Atmel Evaluation Kit AT91SAM9M10-G45-EK AT91SAM9M10-G45-EK Data Sheet

Product codes
AT91SAM9M10-G45-EK
Page of 1361
 909
SAM9M10 [DATASHEET]
6355F–ATARM–12-Mar-13
 
1.
Close the switches on the inputs X
P
 and X
M
 during the Sample and Hold Time.
2.
Convert Channel X
M
 and store the result in TSADCC_CDR1.
3.
If Channel 4 to Channel 7 are enabled, convert Channels and store result in the corresponding 
TSADCC_CDRx and TSADCC_LCDR. 
4.
Set Trigger Counter to 3.
• For Trigger Counter at 3:
1.
Close the switches on the inputs X
P
 and X
M
 during the Sample and Hold Time. 
2.
Convert Channel X
P
, subtract TSADCC_CDR1 from the result and store the subtraction result in 
TSADCC_CDR0 (and also in TSADCC_LCDR if PDCEN is enabled).
3.
If Channel 4 to Channel 7 are enabled, convert Channels and store result in the corresponding 
TSADCC_CDRx and TSADCC_LCDR.
4.
Set Trigger Counter to 4.
• For Trigger Counter at 4:
1.
Close the switches on the inputs X
P
 and X
M
 during the Sample and Hold Time.
2.
Convert Channel Y
P
 and store the result in TSADCC_XPDR, subtract TSADCC_CDR1 from the result 
and store the subtraction result in TSADCC_CDR1 (and also in TSADCC_LCDR if PDCEN is enabled).
3.
If Channel 4 to Channel 7 are enabled, convert Channels and store result in the corresponding 
TSADCC_CDRx and TSADCC_LCDR.
4.
Set Trigger Counter to 5.
• For Trigger Counter at 5:
1.
Close the switches on the inputs Y
and Y
M
 during the Sample and Hold Time.
2.
Convert Channel Y
M
 and store the result in TSADCC_CDR3 (and store content of TSADCC_XPDR in 
TSADCC_LCDR if PDCEN is enabled).
3.
If Channel 4 to Channel 7 are enabled, convert Channels and store result in the corresponding 
TSADCC_CDRx and TSADCC_LCDR.
4.
Set Trigger Counter to 6.
• For Trigger Counter at 6:
1.
Close the switches on the inputs Y
and Y
M
 during the Sample and Hold Time.
2.
Convert Channel Y
P
, subtract TSADCC_CDR3 from the result and store the subtraction result in 
TSADCC_CDR2 (and also in TSADCC_LCDR if PDCEN is enabled).
3.
If Channel 4 to Channel 7 are enabled, convert Channels and store result in the corresponding 
TSADCC_CDRx and TSADCC_LCDR. 
4.
Set Trigger Counter to 7.
• For Trigger Counter at 7:
1.
Close the switches on the inputs Y
and Y
M
 during the Sample and Hold Time
2.
Convert Channel X
P
, subtract TSADCC_CDR3 from the result and store the subtraction result in 
TSADCC_CDR3 (and also in TSADCC_LCDR if PDCEN is enabled).
3.
If Channel 4 to Channel 7 are enabled, convert Channels and store result in the corresponding 
TSADCC_CDRx and TSADCC_LCDR.
4.
Set Trigger Counter to 8.