Linear Technology DC1033A - LTC2952 Push-Button Power Path Controller w/ Supervisor DC1033A DC1033A Data Sheet

Product codes
DC1033A
Page of 6
2
dc1012af
DEMO MANUAL DC1012A
QUICK START PROCEDURE
HARDWARE SETUP
Connect the DC1012A to a DC590 USB serial controller 
using the supplied 14-conductor ribbon cable. Connect 
the DC590 to host PC with a standard USB A/B cable. 
Run the evaluation software supplied with the DC590 or 
downloaded from www.linear.com/software. The correct 
program will be loaded automatically. Click the COLLECT 
button to start reading the input voltage. The software 
allows for selecting the input channel, single ended or dif-
ferential mode and 50Hz/60Hz rejection settings. Selecting 
2
× speed located at the bottom of the strip-chart display 
will double the data output rate at the expense of offset 
accuracy (LTC2499 and LTC2495 only).
Tools are available for logging data, changing reference 
voltage, changing the number of points in the strip chart 
and histogram, and changing the number of points aver-
aged for the DVM display.
Jumpers
JP1,  JP3
 – Select  the  source  for  REF+  and  REF–,  re-
spectively. REF+ can be 5.00V from the onboard LT1236 
reference (default) or supplied externally. REF– can be 
ground (0V, default) or supplied externally.
JP2 – Select source for analog COM input, either tied to 
ground or supplied externally to the COM turret post.
JP4 – JP6 – (CA0-CA2) Address select lines. Lines may 
be 1, 0 or floating for a total of 27 different addresses. 
The default setting is all 1s.
Connection to DC590 Serial Controller
J2 is the power and digital interface connector. Connect to 
a DC590 serial controller with the supplied 14-conductor 
ribbon cable. Digital signals are also connected to through-
hole test points on the circuit board.
Analog Connections
Analog signal connections are made via the row of turret 
posts along the edge of the board. Also, if you are connect-
ing the board to an existing circuit, the exposed ground 
planes along the edges of the board may be used to form 
a solid connection between grounds.