When the address match logic detects a match, INTFLAG.AMATCH is set and STATUS.DIR is updated to indicate 
whether it is a read or a write transaction.
z
Bit 0 – GENCEN: General Call Address Enable
Writing a one to GENCEN enables general call address recognition. A general call address is an address of all 
zeroes with the direction bit written to zero (master write).
0: General call address recognition disabled.