Linear Technology LTM4601AEV DEMO BOARD µModule Regulator DC1414A DC1414A Data Sheet

Product codes
DC1414A
Page of 6
2
dc1414af
DEMO MANUAL DC1414A
QUICK START PROCEDURE
Demonstration circuit 1414 is easy to set up to evaluate the 
performance of the LTM4601AEV. Please refer to Figure 1 
for proper measurement equipment setup and follow the 
procedure below: 
1. Place jumpers in the following positions for a typical 
1.5V
OUT
 application:
V
OUT
 SELECT
RUN
MARG0
MARG1
1.5V
ON
LO
LO
2. With the power off, connect the input power supply, 
load and meters as shown in Figure 1. Preset the load 
to 0A and V
IN
 supply between 5V to 20V. 
3. Turn on the power at the input. The output voltage 
should be 1.5V ± 1%.
4. Once the proper output voltage is established, adjust 
the load within the operating range and observe the 
output voltage regulation, ripple voltage, efficiency and 
other parameters. Output ripple should be measured at 
J4 with a BNC cable. 
5. (Optional) To review load transient performance, apply 
an adjustable pulse signal between IOSTEP (E3) and 
GND pins. Pulse amplitude sets the current step. The 
pulse signal should have very small duty cycle (<15%) 
to limit the thermal stress on the transient load circuit. 
The output transient current can be monitored at BNC 
connector J3 (10mV/A).
6. (Optional) To implement output voltage margining, 
place jumpers MARG0 and MARG1 in the configuration 
shown according to the table below. The output voltage 
measured at J4 will respond accordingly. 
MARG1
MARG0
∆V
OUT
LO
LO
0
LO
HI
5%
HI
LO
–5%
HI
HI
0