Linear Technology LTM4601AEV DEMO BOARD µModule Regulator DC1414A DC1414A Data Sheet
![Linear Technology](https://files.manualsbrain.com/attachments/ca6c3265af67c4d48ccaa023657338a9ff23fb20/common/fit/150/50/6941500f9732baeb611cb3c2aaf59b308d9b3ff63f239af1a3af62976f9d/brand_logo.gif)
Product codes
DC1414A
2
dc1414af
DEMO MANUAL DC1414A
QUICK START PROCEDURE
Demonstration circuit 1414 is easy to set up to evaluate the
performance of the LTM4601AEV. Please refer to Figure 1
for proper measurement equipment setup and follow the
procedure below:
1. Place jumpers in the following positions for a typical
1. Place jumpers in the following positions for a typical
1.5V
OUT
application:
V
OUT
SELECT
RUN
MARG0
MARG1
1.5V
ON
LO
LO
2. With the power off, connect the input power supply,
load and meters as shown in Figure 1. Preset the load
to 0A and V
IN
supply between 5V to 20V.
3. Turn on the power at the input. The output voltage
should be 1.5V ± 1%.
4. Once the proper output voltage is established, adjust
the load within the operating range and observe the
output voltage regulation, ripple voltage, efficiency and
other parameters. Output ripple should be measured at
J4 with a BNC cable.
5. (Optional) To review load transient performance, apply
an adjustable pulse signal between IOSTEP (E3) and
GND pins. Pulse amplitude sets the current step. The
pulse signal should have very small duty cycle (<15%)
to limit the thermal stress on the transient load circuit.
The output transient current can be monitored at BNC
connector J3 (10mV/A).
6. (Optional) To implement output voltage margining,
place jumpers MARG0 and MARG1 in the configuration
shown according to the table below. The output voltage
measured at J4 will respond accordingly.
MARG1
MARG0
∆V
OUT
LO
LO
0
LO
HI
5%
HI
LO
–5%
HI
HI
0