2 - In Dual slope mode a Retrigger Event does not clear the TCC counter.
Errata reference: 12354
Errata reference: 12354
Fix/Workaround:
None
3 - In two ramp mode, two events will be generated per cycle, one on each
ramp’s end. EVCTRL.CNTSEL.END cannot be used to identify the end of a
double ramp cycle. Errata reference: 12224
ramp’s end. EVCTRL.CNTSEL.END cannot be used to identify the end of a
double ramp cycle. Errata reference: 12224
Fix/Workaround:
None
4 - If an input event triggered STOP action is performed at the same time as
the counter overflows, the first pulse width of the subsequent counter start
can be altered with one prescaled clock cycle. Errata reference: 12107
the counter overflows, the first pulse width of the subsequent counter start
can be altered with one prescaled clock cycle. Errata reference: 12107
Fix/Workaround:
None
5 - When the RUNSTDBY bit is written after the TCC is enabled, the
respective TCC APB bus is stalled and the RUNDSTBY bit in the TCC CTRLA
register is not enabled-protected. Errata reference: 12477
respective TCC APB bus is stalled and the RUNDSTBY bit in the TCC CTRLA
register is not enabled-protected. Errata reference: 12477
Fix/Workaround:
None.
6 - TCC fault filtering on inverted fault is not working. Errata reference:
12512
12512
Fix/Workaround:
Use only non-inverted faults.
7 - When waking up from the STANDBY power save mode, the
SYNCBUSY.CTRLB and SYNCBUSY.STATUS bits may be locked to 1. Errata
reference: 12227
SYNCBUSY.CTRLB and SYNCBUSY.STATUS bits may be locked to 1. Errata
reference: 12227
Fix/Workaround:
After waking up from STANDBY power save mode, perform a software reset of
the TCC if you are using the SYNCBUSY.CTRLB and SYNCBUSY.STATUS bits
the TCC if you are using the SYNCBUSY.CTRLB and SYNCBUSY.STATUS bits
8 - When the Peripheral Access Controller (PAC) protection is enabled,
writing to WAVE or WAVEB registers will not cause a hardware exception.
Errata reference: 11468
writing to WAVE or WAVEB registers will not cause a hardware exception.
Errata reference: 11468
Fix/Workaround:
None