MFR_VINEN_UV_FAULT_RESPONSE
This command register determines whether V
This command register determines whether V
OUT
undervoltage faults from a given channel cause the V
IN_EN
pin to be
pulled low.
MFR_VINEN_UV_FAULT_RESPONSE Data Contents
BIT(S) SYMBOL
OPERATION
b[7]
Mfr_vinen_uv_fault_response_chan7
Response to channel 7 VOUT_UV_FAULT.
1 = Disable (pull low) V
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[6]
Mfr_vinen_uv_fault_response_chan6
Response to channel 6 VOUT_UV_FAULT.
1 = Disable (pull low) V
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[5]
Mfr_vinen_uv_fault_response_chan5
Response to channel 5 VOUT_UV_FAULT.
1 = Disable (pull low) V
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[4]
Mfr_vinen_uv_fault_response_chan4
Response to channel 4 VOUT_UV_FAULT.
1 = Disable (pull low) V
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[3]
Mfr_vinen_uv_fault_response_chan3
Response to channel 3 VOUT_UV_FAULT.
1 = Disable (pull low) V
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[2]
Mfr_vinen_uv_fault_response_chan2
Response to channel 2 VOUT_UV_FAULT.
1 = Disable (pull low) V
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[1]
Mfr_vinen_uv_fault_response_chan1
Response to channel 1 VOUT_UV_FAULT.
1 = Disable (pull low) V
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[0]
Mfr_vinen_uv_fault_response_chan0
Response to channel 0 VOUT_UV_FAULT.
1 = Disable (pull low) V
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.