Linear Technology LTC2977 Demo Board: Octal Power Supply Manager [Requires DC1613] DC2028A DC2028A Data Sheet

Product codes
DC2028A
Page of 94
LTC2977
68
2977fa
For more information 
pMbus coMManD DescripTion
MFR_FAULT_LOG_CLEAR
This command initializes the EEPROM block reserved for fault logging. Any previous fault log stored in EEPROM will 
be erased by this operation and logging of the fault log RAM to EEPROM will be enabled.
MFR_FAULT_LOG_STATUS
Read only. This register is used to manage fault log events.
Mfr_fault_log_status_eeprom is set after a MFR_FAULT_LOG_STORE command or a faulted-off event triggers a transfer 
of the fault log from RAM to EEPROM. This bit is cleared by a MFR_FAULT_LOG_CLEAR command.
Mfr_fault_log_status_ram is set after a MFR_FAULT_LOG_RESTORE to indicate that the data in the RAM has been 
restored from EEPROM and not yet read using a MFR_FAULT_LOG command. This bit is cleared by a successful 
execution of an MFR_FAULT_LOG command, or by a successful execution of an MFR_FAULT_LOG_CLEAR command.
MFR_FAULT_LOG_STATUS Data Contents
BIT(S) SYMBOL
OPERATION
b[1] Mfr_fault_log_status_ram
Fault log RAM status:
0: The fault log RAM allows updates.
1: The fault log RAM is locked until the next MFR_FAULT_LOG read.
b[0] Mfr_fault_log_status_eeprom Fault log EEPROM status:
0: The transfer of the fault log RAM to the EEPROM is enabled.
1: The transfer of the fault log RAM to the EEPROM is inhibited.
Figure 14. Fault Log Conceptual Diagram
2977 F14
ADC READINGS
CONTINUOUSLY
FILL BUFFER
TIME OF FAULT
TRANSFER TO
EEPROM AND
LOCK
AFTER FAULT
READ FROM 
EEPROM AND
LOCK BUFFER
RAM 255 BYTES
EEPROM 255 BYTES
8
...
...