•  DAC manual with soft-connect. Non servo mode. The 
DAC soft-connects to the feedback node. Soft-connect 
drives the DAC code to match the voltage at the feedback 
node. After connection, the DAC is moved by writing 
DAC codes to the MFR_DAC register.
•  DAC manual with hard-connect. Non servo mode. The 
DAC  hard-connects  to  the  feedback  node  using  the 
current value in MFR_DAC. After connection, the DAC is 
moved by writing DAC codes to the MFR_DAC register.
Margining
The LTC2977 margins and trims the output of a DC/DC 
converter by forcing a voltage across an external resistor 
connected between the DAC output and the feedback node 
or the trim pin. Preset limits for margining are stored in 
the VOUT_MARGIN_HIGH/LOW registers. Margining is 
actuated by writing the appropriate bits to the OPERA-
TION register. 
Margining  requires  the  DAC  to  be  connected.  Margin 
requests that occur when the DAC is disconnected will 
be ignored.
Off Sequencing
An off sequence is initiated using the CONTROL pin or the 
OPERATION command. The TOFF_DELAY value determines 
the amount of time that elapses from the beginning of the 
off sequence until each channel’s V
OUT_EN
 pin is pulled 
low, thus disabling its DC/DC converter. 
V
OUT
 Off Threshold Voltage
The  MFR_VOUT_DISCHARGE_THRESHOLD  command 
register allows the user to specify the OFF threshold that 
the output voltage must decay below before the channel 
can enter/re-enter the ON state. The OFF threshold voltage 
is  specified  by  multiplying  MFR_VOUT_DISCHARGE_
THRESHOLD and VOUT_COMMAND. In the event that an 
output voltage has not decayed below its OFF threshold 
before attempting to enter the ON state, the channel will 
continue to be held off, the appropriate bit is set in the 
STATUS_MFR_SPECIFIC  register,  and  the  ALERTB  pin 
will be asserted low. When the output voltage has decayed 
below its OFF threshold, the channel can enter the ON state.
Automatic Restart Via MFR_RESTART_DELAY 
Command and CONTROLn pin
An automatic restart sequence can be initiated by driving 
the CONTROL pin to the off state for >10μs then releasing 
it. The automatic restart disables all V
OUT_EN
 pins that are 
mapped to a particular CONTROL pin for a time period 
=  MFR_RESTART_DELAY  and  then  starts  all  DC-DC 
Converters according to their respective TON_DELAYs. 
(See Figure 18). V
OUT_ENn
 pins are mapped to one of the 
CONTROL pins by the MFR_CONFIG_LTC2977 command. 
This feature allows a host that is about to reset to restart 
the power in a controlled manner after it has recovered. 
applicaTions inForMaTion
FAULT MANAGEMENT
Output Overvoltage and Undervoltage Faults
The  high  speed  voltage  supervisor  OV  and  UV  fault 
thresholds are configured using the VOUT_OV_FAULT_
LIMIT  and  VOUT_UV_FAULT_LIMIT  commands, 
respectively.  The  VOUT_OV_FAULT_RESPONSE  and 
VOUT_UV_FAULT_RESPONSE commands determine the 
responses to OV/UV faults. Fault responses can range from 
disabling  the  DC/DC  converter  immediately,  waiting  to 
see if the fault condition persists for some interval before 
disabling  the  DC/DC  converter,  or  allowing  the  DC/DC 
converter to continue operating in spite of the fault. If a DC/
DC converter is disabled, the LTC2977 can be configured 
to  retry  one  to  six  times,  retry  continuously  without 
limitation, or latch-off. The retry interval is specified using 
the MFR_RETRY_DELAY command. Latched faults are 
reset by toggling the CONTROL pin, using the OPERATION 
command, or removing and reapplying the bias voltage to 
the V
IN_SNS
 pin. All fault and warning conditions result in 
Figure 18. Off Sequence with Automatic Restart
V
CONTROL
V
OUT_END
CONTROL
PIN BOUNCE
TOFF_DELAY0
TON_DELAY0
2977 F18
MFR_RESTART_DELAY