Figure 1: UNI-REG additional board
How to connect the board?
The UNI-REG additional board is connected to the power supply source via a screw connector CN1. The regulated 
voltage is delivered via a screw connector CN2. Voltage value to be supplied to the CN2 connector is selected by 
jumpers J1-J5, Figure 2. Next to each jumper, there is a designation indicating the voltage to be selected by using these 
jumpers. When jumpers are not placed, the output voltage is 12V, provided that the output voltage is higher than 12V, 
Figure 2F.
UNI-REG
The UNI-REG additional board is used to reduce and stabilize input voltage to the values selected by jumpers. 
Key features:
- 7-23V AC or 9-32V DC input voltage;
- 1.8, 2.7, 3.3, 4, 5 or 12V output voltage;
- Up to 3A output current; 
Figure 2: Jumpers