L6472
Phase current control
70
The maximum fast decay duration is set by the TOFF_FAST value.
Figure 17. Adaptive decay - fast decay tuning
When two or more fast decays are performed with the present target current, the control 
system adds a fast decay at the end of every OFF time, keeping the OFF state duration 
constant (t
OFF
 is split into t
OFF,SLOW
 and t
OFF,FAST
). When the current threshold is increased 
by a microstep change (rising step), the system returns to normal decay mode (slow decay 
only) and the t
FAST
 value is halved.
Stopping the motor or reaching the current sine wave zero crossing causes the current 
control system to return to the reset state.