Any attempt to write the register when the motor is running causes the command to be 
ignored and the NOTPERF_CMD flag to rise (see 
When when SYNC_EN bit is set low, BUSY/SYNC output is forced low during the 
commands execution, otherwise, when the SYNC_EN bit is set high, the BUSY/SYNC 
output provides a clock signal according to the SYNC_SEL parameter.
         
The synchronization signal is obtained starting from the electrical position information 
(EL_POS register) according to 
:
         
Table 21. SYNC output frequency
STEP_SEL (f
FS
 is the full-step frequency) 
000 001 010 011 100 101 110 111 
SYNC_SEL 
000 
f
FS
/2 f
FS
/2 f
FS
/2 f
FS
/2 f
FS
/2 f
FS
/2 f
FS
/2 f
FS
/2 
001 
NA f
FS
 
f
FS
 
f
FS
 
f
FS
 
f
FS
 
f
FS
 
f
FS
 
010 
NA 
NA 
2 · f
FS
 
2 · f
FS
 2 
· 
f
FS
 
2 · f
FS
 2 
· 
f
FS
 
2 · f
FS
 
011 
NA NA NA 
· 
f
FS
 4 
· 
f
FS
 
4 · f
FS
 4 
· 
f
FS
 
4 · f
FS
 
100 
NA NA NA NA 
· 
f
FS
 
8 · f
FS
 8 
· 
f
FS
 
8 · f
FS
 
101 
NA NA NA NA NA NA NA NA 
110 
NA NA NA NA NA NA NA NA 
111 
NA NA NA NA NA NA NA NA 
Table 22. SYNC signal source
SYNC_SEL[2 … 0] 
Source 
0 0 0 
EL_POS[7] 
0 0 1 
EL_POS[6] 
0 1 0 
EL_POS[5] 
0 1 1 
EL_POS[4] 
1 0 0 
EL_POS[3] 
1 0 1 
UNUSED 
(1)
 
1. When this value is selected the BUSY output is forced low.
1 1 0 
1 1 1