STMicroelectronics A 200 W ripple-free input current PFC pre-regulator with the L6563S EVL6563S-200ZRC EVL6563S-200ZRC Data Sheet

Product codes
EVL6563S-200ZRC
Page of 39
AN3180
A 200 W ripple-free input current PFC pre-regulator
Doc ID 17273 Rev 1
25/39
   
   
   
The waveforms of 
 are taken at full load. The images in 
 an
 
show the mains voltage and current drawn from the mains: this is quite sinusoidal, as in a 
standard transition mode PFC converter. In fact its harmonic content is well below the 
maximum allowed by current regulations (JEITA-MITI and European EN61000-3-2), as can 
be seen from
 and 
. Also the power factor and the total harmonic distortion 
parameters are as good as for a standard circuit without the cancellation winding, as can be 
seen from 
, where also the efficiency measurements are plotted, showing values 
always greater than 91.7 %.
The zoomed image of 
 (@115 Vac) shows a residual ripple current in the DC 
winding of 180 mA pk-pk, against a 6.053 A pk-pk of the AC winding current (which would 
flow in the boost inductor in the conventional topology arrangement), and so resulting in 
0.18/6.053 = 29.7*10-3 (-30.5 dB) attenuation.
Figure 17.
Line current and voltage @ full load 
(200 W) - Line current and voltage 
@ 115 Vac -200 W
Figure 18.
Line current and voltage @ full load 
(200 W) - Line current and voltage 
@ 230 Vac -200 W
         
         
Figure 19.
AC and DC winding currents 
nominal input voltages and full load 
(200 W) - AC and DC winding 
currents @ 115 Vac - 200 W
Figure 20.
AC and DC winding currents 
nominal input voltages and full load 
(200 W) - AC and DC winding 
currents @ 230 Vac - 200 W