2. Construction 
stage 
II: 
Connection/start-up 
2.1 
After the components have been placed on the printed circuit board and the 
board has been checked for possible faults (cold solder joints, solder straps, 
etc.), a first functional test can be conducted. 
2.2
 
Bring both the trimmer potentiometers in the middle position. 
2.3
 
Note that the this component may be powered only with a screened direct current 
from a power supply unit or with a battery, which can also provide the necessary 
current. Car chargers or toy-railway transformers are not suitable sources of 
power and can cause damage of the components or else can lead to a non-
functioning of the assemblies. 
2.4
 
Solder now the temperature sensor (KTY 10 = KTY 81/220 B) at the attachment 
shoes by means of a piece of cable and attach these on the solder pin marked as 
“sensor”. The sensor can have any polarity. In order to protect the sensor 
connections against moisture, the sensor should be covered with a shrink tubing.