Peter Electronic FUS 075/EV/IP65 0.75 kW 1-phase frequency inverter, 200 - 240 V to , 2F700.23075 2F700.23075 Data Sheet

Product codes
2F700.23075
Page of 102
Quick Start Guide 
This guide is to assist in installing and running the inverter to verify that the drive and motor 
are working properly. Starting, stopping and speed control will be from the keypad. If your 
application requires external control or special system programming, consult the 7300EV 
Instruction Manual supplied with your inverter. 
 
Step 1 Before starting the inverter 
Please refer to chapter one (Preface) and chapter two (Safety Precautions) of the 7300EV 
Instruction Manual. Verify drive was installed in accordance with the procedures as 
described in chapter three (Environment description and installation). If you feel this was 
abnormal, do not start the drive until qualified personnel have corrected the situation. 
(Failure to do so could result in serious injury.) 
 
•  Check inverter and motor nameplates to determine that they have the same HP and voltage 
ratings. (Ensure that full load motor amps do not exceed that of the inverter.) 
•  Remove the terminal cover to expose the motor and power terminals. 
a. Verify that AC power is wired to L1(L), L2, and L3(N) . 
b. Verify that Motor leads are connected to T1, T2, and T3 . 
c. IF brake module is necessary, please connect terminal voltage of the braking unit to + 
and - of the inverter. 
 
 
          
 
 
Step2 Apply power to the drive.
 
Apply AC power to the drive and observe operator. Three 7-segment display should show 
power voltage for 3~5 seconds and then show Frequency Command, factory sets 5.00. 
(Frequency Command of 7-segment display should be flashed all the time.)
 
Power Indicator