Transmotec V Linear Actuator, 200mm Stroke, 1200N, 7.5mm/s, DLA-24-40-A-200-POT-IP65 16024264CR Data Sheet

Product codes
16024264CR
Page of 1
 
KG
KG
Load
Side Load
Transmotec
Transmotec
www.transmotec.com
The load should be centered on the operating direction
Side  load  is  NOT  good  for  the  actuator.  In  case  the              
actuator rod is exposed to side load the service life time 
will be reduced
.



● 
Load force up to 1000N
Static force 2300N
Operating temperature -26°C~+65°C
Duty cycle 25% (25% on / 75% off) 
2.5 minutes continuous operation followed by 7.5 minutes off
The actuator will extend when the red wire connects to plus and black wire to negative, reverse them for retraction.
Make sure the actuator is not connected electrically when installed. 
Make sure you use the correct DC voltage.
Actuator force must not be over loaded. Please refer to the model number and it’s force specification. 
To avoid over load disconnect the actuator if the current exceed it’s maximum rating.
The actuator have integrated limit switches that will stop the rod when it reach it’s end position of extraction or retraction.
In order to retract or extract again the supply voltage polarity must be reverted.
Notes
DLA INSTALLATION MANUAL
kg
= Limit switch
 
KG
KG
Load
Side Load
kg
© Copyright Transmotec
MODEL NO. DESIGNATIONS
DLA
12
20
A
200
POT-IP65
Type
Voltage
12V DC
24V DC
Gear Ratio
10:1
40:1
ACME
(screw 
standard)
Stroke
50mm
100mm
200mm
300mm
Potentiometer Sensor 
and IP-Class 65
 (Exact)
10.9:1
42.8:1
Current vs Load
200      400     600     800     1000   1200   1400 
5:1 10:1
30:1
40:1
20:1
Speed vs Load
200      400     600     800     1000   1200  1400
50
40
30
20
10
5:1
10:1
30:1
40:1
20:1
Max. Load
Rated Load