Siemens SINAMICS G110 0.12 kW 1-phase frequency inverter, 230 Vac to , 6SL3211-0AB11-2BA1 6SL3211-0AB11-2BA1 Data Sheet

Product codes
6SL3211-0AB11-2BA1
Page of 84
04/2003 
Electro-Magnetic Compatibility (EMC) 
SINAMICS G110    Operating Instructions 
 
6SL3298-0AA11-0BP0 
67
 
9.1.4  Three general cases of EMC performance are applicable 
as detailed below 
Case 1: General Industrial 
Compliance with the EMC Product Standard for Power Drive Systems EN 61800-3 
for use in Second Environment (Industrial) and Restricted Distribution
Table 9-2 
Case 1 - General Industrial 
EMC Phenomenon 
Standard 
Level 
Radiated Emissions 
EN 55011 
Level Group 1, Class A 
Emissions 
Conducted Emissions 
EN 61800-3 
Limits are equivalent to EN55011, Class A, 
group 2 
Electrostatic Discharge 
EN 61000-4-2 
8 kV air discharge  
Burst Interference 
EN 61000-4-4 
2 kV power cables (Level 3), 1 kV control 
(Level 3) 
Immunity: 
Radio Frequency 
Electromagnetic Field 
EN 61000-4-3 
26-1000 MHz, 10 V/m 
Case 2: Filtered Industrial 
This level of performance will allow the manufacturer/assembler to self-certify their 
apparatus for compliance with the EMC directive for the industrial environment as 
regards the EMC performance characteristics of the power drive system. 
Performance limits are as specified in the Generic Industrial Emissions and 
Immunity standards EN 50081-2 and EN 61000-6-2. 
Table 9-3 
Case 2 - Filtered Industrial 
EMC Phenomenon 
Standard 
Level 
Radiated Emissions 
EN 55011 
Level Group 1, Class A 
Emissions: 
Conducted Emissions 
EN 61800-3 
Limits are equivalent to EN55011, Class A, 
group 2 
Supply Voltage Distortion 
EN 61000-2-4  
 
Voltage Fluctuations, Dips, 
Unbalance, Frequency 
Variations 
EN 61000-2-1 
 
Electrostatic Discharge 
EN 61000-4-2 
8 kV air discharge  
Burst Interference 
EN 61000-4-4 
2 kV power cables (Level 3), 2 kV control 
(Level 4) 
Immunity: 
Radio Frequency 
Electromagnetic Field, 
amplitude modulated 
EN 61000-4-3 
80-1000 MHz, 10 V/m, 80% AM, power and 
signal lines