Siemens SINAMICS G110 0.12 kW 1-phase frequency inverter, 230 Vac to , 6SL3211-0AB11-2BA1 6SL3211-0AB11-2BA1 Data Sheet
Product codes
6SL3211-0AB11-2BA1
04/2003
Electro-Magnetic Compatibility (EMC)
SINAMICS G110 Operating Instructions
6SL3298-0AA11-0BP0
67
9.1.4 Three general cases of EMC performance are applicable
as detailed below
Case 1: General Industrial
Compliance with the EMC Product Standard for Power Drive Systems EN 61800-3
for use in Second Environment (Industrial) and Restricted Distribution.
for use in Second Environment (Industrial) and Restricted Distribution.
Table 9-2
Case 1 - General Industrial
EMC Phenomenon
Standard
Level
Radiated Emissions
EN 55011
Level Group 1, Class A
Emissions
Conducted Emissions
EN 61800-3
Limits are equivalent to EN55011, Class A,
group 2
group 2
Electrostatic Discharge
EN 61000-4-2
8 kV air discharge
Burst Interference
EN 61000-4-4
2 kV power cables (Level 3), 1 kV control
(Level 3)
(Level 3)
Immunity:
Radio Frequency
Electromagnetic Field
Electromagnetic Field
EN 61000-4-3
26-1000 MHz, 10 V/m
Case 2: Filtered Industrial
This level of performance will allow the manufacturer/assembler to self-certify their
apparatus for compliance with the EMC directive for the industrial environment as
regards the EMC performance characteristics of the power drive system.
Performance limits are as specified in the Generic Industrial Emissions and
Immunity standards EN 50081-2 and EN 61000-6-2.
apparatus for compliance with the EMC directive for the industrial environment as
regards the EMC performance characteristics of the power drive system.
Performance limits are as specified in the Generic Industrial Emissions and
Immunity standards EN 50081-2 and EN 61000-6-2.
Table 9-3
Case 2 - Filtered Industrial
EMC Phenomenon
Standard
Level
Radiated Emissions
EN 55011
Level Group 1, Class A
Emissions:
Conducted Emissions
EN 61800-3
Limits are equivalent to EN55011, Class A,
group 2
group 2
Supply Voltage Distortion
EN 61000-2-4
Voltage Fluctuations, Dips,
Unbalance, Frequency
Variations
Unbalance, Frequency
Variations
EN 61000-2-1
Electrostatic Discharge
EN 61000-4-2
8 kV air discharge
Burst Interference
EN 61000-4-4
2 kV power cables (Level 3), 2 kV control
(Level 4)
(Level 4)
Immunity:
Radio Frequency
Electromagnetic Field,
amplitude modulated
Electromagnetic Field,
amplitude modulated
EN 61000-4-3
80-1000 MHz, 10 V/m, 80% AM, power and
signal lines
signal lines