Deditec RO-ETH MODUL 64 OC IN / 64 RELAIS OUT RO-ETH-O64-R64 Data Sheet

Product codes
RO-ETH-O64-R64
Page of 379
R estore basic configuration | Seite
24
5. Restore basic configuration
5.1. Restore IP address
The default value of the IP address is: 192.168.1.1
Left Button:
Restore IP address to default (192.168.1.1):
To restore the IP address proceed as follow:
Push the button at least 5 sec.
After  that,  the  left  LEDs  "CPU  Activity"  and  "Interface  Activity"  should  be
flashing four times (confirmation of receipt)
After this, the module has following settings: 
IP address
192.168.1.1
Subnet mask
255.255.255.0
Standard gateway 192.168.1.254
5.2. Restore firmware
To restore the firmware to default value proceed as follow:
Right Button:
Restore firmware to factory settings
To restore the firmware to factory settings proceed as follow:
Press the button at least 10sec.
After  this,  the  three  LED‘s  “CPU  Activity”,  “Interface  Activity”  and  “Status”
should be flashing four times (confirmation of receipt).
After this, the module restarts. 
The firmware and configuration of the factory settings are now active again!