Tripp Lite OmniVS 120V 1000VA 500W Line-Interactive UPS, Tower, USB port OMNIVS1000 User Manual

Product codes
OMNIVS1000
Page of 4
USB port and cable enables unattended shutdown in the case of extended power failure
Built-in RJ45 TEL/Ethernet suppression jacks protect modem, fax machine, cordless phone or other peripheral with a standard single-line
tel/DSL or data line connection
Audible alarm and 4 front panel LEDs offer complete UPS and line power status information
1000VA/500 watt power handling ability supports a variety of sensitive electronic equipment 
3.5 minutes full load runtime (1000VA/500 watts), 14 minutes half load runtime (500VA/250 watts) 
Supports battery replacement via built-in access panel
Short circuit protection in AC and battery mode
2 year product warranty
$200,000 
Specifications
SYSTEM OVERVIEW
Voltage compatibility
120V AC
Frequency
compatibility
60Hz
OUTPUT
Output VA
1000
Output watts
500
Output nominal
voltage
120V AC
Output voltage
regulation
BATTERY MODE: PWM sine wave 115V +/-5%
Output frequency
regulation
LINE MODE: Passes line frequency of 60Hz +/-10% BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz
Outlet quantity / type
8 NEMA 5-15R
INPUT
Maximum input amps
12A / 1440 watts
Input connection type
NEMA 5-15P, right-angle plug
Input cord length
6 ft., 14 gauge
Recommended
electrical service
15A 120V
BATTERY
Full load runtime
3.5 minutes (1000VA / 500 watts)
Half load runtime
14 minutes (500VA / 250 watts)
DC system voltage
12 V DC
Typical battery
lifespan
3-6 years, depending on usage
Battery recharge rate
2-4 hours to 90%
Replacement Battery
Cartridge
VOLTAGE REGULATION
Voltage regulation
description
Line interactive voltage regulation corrects brownouts as low as 83V back to usable values
Direct pass through
Voltages of 106V and greater are passed through to connected equipment unchanged
Brownout correction
Input voltages between 83 and 105 are boosted by 14%
LEDS ALARMS & SWITCHES
Front panel LEDs
4 front panel LEDs indicate line power status, battery power status, battery low/replace status and overload