LD6A LED SignaLights
Safety Precautions
Turn off the power to the LD6A before mounting, dis-
 
mounting, wiring, and assembling the LED module. Make 
sure of correct wiring, otherwise electrical shocks or fire 
hazard may result.
Mount the LD6A on a solid surface not subjected to vibra-
 
tions.
Do not mount the LD6A upside-down or horizontally.
 
Do not leave the LD6A without a cap or unassembled.
 
Install the supplied gasket, otherwise the waterproof char-
 
acteristic is impaired.
Do not apply any chemicals which may corrode the plastic 
 
materials.
If the LD6A is subjected to strong vibrations, the hexa-
 
gon socket screw may become loose. Take measures to 
prevent loosening. (See the figure below.)
2-M4 holes for hexagon socket 
set screws
(recommended tightening torque:
1.1 to1.2 N・m)
Do not loosen a screw for which the tightening torque is 
 
not specified.
Instructions
Mounting
See drawing below on mounting of the LD6A.
 
For panel cut-out, see pages 9 and 10.
 
Face the LD6A to the front to make sure the alarm sound 
 
is clear. (Steady/flashing/alarm) 
Frame Mounting
1.  Insert two nuts in the frame, and attach the bracket us-
ing two M5 screws. 
Recommended tightening torque: 2.6 to 2.7 N·m
2.  Mount the LD6A to the bracket using four M4 screws. 
Recommended tightening torque: 1.6 to 1.7 N·m
Note:  See table below for typical examples of frames and 
nuts. Consult the manufacturer of the frame for the 
installation method of the frame nut.
Examples of recommended frames and frame nuts
 
Frame Size
Frame
Frame Nut
Manufacturer
30 mm
(Note)
SFF-302
SFB-001
SFB-4B5
SFB-101
SUS 
Corporation 
(Japan)
40 mm
SFF-402
SFB-008
SFB-4A5
SFB-108
Note:  The mounting bracket for the housing is 40 mm.
 
When using a frame mount type, be sure to 
use flexible conduit, otherwise the waterproof 
characteristic is impaired.
Refer to the “Example of Flexible Conduit” 
shown on the right.
Example of Flexible Conduit
 
Conduit Port Size
M20
Gland
AL16/M20/A/BL
Conduit 
PAFS16BL
Manufacturer
Adaptaflex
Frame (Note)
Frame Nut (Note)
Bracket
Plain Washer
Spring Washer
M5 Screw
M4 Screw, Spring Washer, Plain Washer
Gland
Conduit
Conduit port
(M20×P1.5)
Wall Mounting
1.  Make four tapped holes in the mounting panel and 
mount the bracket and gasket using four screws (M4 x 
20). 
Recommended tightening torque: 1.6 to 1.7 N·m
2.  Mount the LD6A to the bracket using four screws  
(M4 x 8). 
Recommended tightening torque: 1.6 to 1.7 N·m
Direct Mounting
Recommended tightening torque: 
 
2.6 to 2.7 N·m
Pole Mounting (with base)
The pole mount type can be installed in four ways. The 
recommended mounting method (pattern A) is described 
below.
Recommended tightening torque:
2.6 to 2.7 N·m (M5 screw)
Pole Mounting (with L-shaped bracket)
1.  When L-shaped bracket is used
  Recommended tightening torque: 10 to 11 N·m (M10)
  Recommended tightening torque: 25 to 26 N·m (M22)
2.  When L-shaped bracket is not used
  Remove the bushing, hexagonal nut (M22), plain wash-
er, and L-shaped bracket from the LD6A and install in 
order of plain washer, hexagonal nut (M22), and bush-
ing.
  Recommended tightening torque: 25 to 26 N·m (M22)
Panel
Nut
Gasket
Bracket
Plain Washer
Spring Washer
M4 Screw (20 mm)
M4 Screw (8 mm), Spring Washer, Plain Washer
Pole Stand
4-M5 Mounting Hole 
(recommended)
3-M4 Mounting Hole
4-M4 Mounting Hole
4-M5 
Mounting
Hole
M5 Screw
O-ring
Pole Stand
Gasket
Panel
Plain Washer
Spring Washer
Nut
Panel
M5 Screw
Spring Washer
Plain Washer
O-ring
Base
Gasket
Nut