Belden Bus-cable for RS-485-application (CAN-Bus) Grey 9841 Data Sheet

Product codes
9841
Page of 3
 
For more Information 
please call
1-800-Belden1
Description
24 AWG stranded (7x32) TC conductors, polyethylene insulation, twisted pairs, overall Beldfoil® (100% coverage) + TC braid
shield (90% coverage), 24 AWG stranded TC drain wire, PVC jacket.
AWG
 
 # Pairs   AWG   Stranding   Conductor Material 
1.000 
24 
7x32 
TC - Tinned Copper 
Insulation Material
 
 Insulation Material 
PE - Polyethylene 
Outer Shield Material
 
 Layer #  Outer Shield Trade Name   Type   Outer Shield Material 
 Coverage (%)
Beldfoil® 
Tape  Aluminum Foil-Polyester Tape 
100 
 
Braid 
TC - Tinned Copper 
90 
Outer Shield Drain Wire AWG
 
 AWG   Stranding   Drain Wire Conductor Material 
24 
7x32 
TC - Tinned Copper 
Outer Jacket Material
 
 Outer Jacket Material 
PVC - Polyvinyl Chloride 
Overall Nominal Diameter:
Pair Color Code Chart
 
 Color 
White/Blue and Blue/White 
Pair Lay Length & Direction
 
 Lay Length (in.)  Twists/ft. (twist/ft) Direction 
2.500 
4.800 
Left Hand Lay 
Operating Temperature Range
UL Temperature Rating
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
Physical Characteristics (Overall):
Conductor:
Insulation:
Outer Shield:
Outer Jacket:
Overall Cabling:
0.232 in.
Pair:
Mechanical Characteristics (Overall):
-30°C To +80°C
80°C
36 lbs/1000 ft.
72.300 lbs.
2.500 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards:
 
Page 1 of 3 
07-04-2008
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
 
 
9841  Multi-Conductor - Low Capacitance Computer Cable for EIA RS-485 Applications