Lappkabel 2210704, Cable, , Black Sheath 2210704 Data Sheet

Product codes
2210704
Page of 1
U.I. Lapp 
GmbH 
DATA SHEET 
 
 
 
 
 
H01N2-D
 
 
DB2310026EN 
valid from: 2011-08-26 
 
 
Originator: T. Merker / PCM
 
Document: 
DB2310026EN 
page 1 of 1 
All deviations from this specification are subject to explicit consent of U.I. Lapp GmbH. All rights reserved acc. to DIN 34.  
PD 0019/02_10.09EN 
APPLICATION 
 
 
(HD 516) 
Within the cable type standard HD 22.6, H01N2-D is titled as “arc welding cable”. The application of H01N2-D ◄HAR► single-core rubber cables is de-
fined in HD 516. According to both norms, H01N2-D is applicable for the connection of handheld arc welding devices/electrodes for the transmission of 
high currents between the electric welding machine and the welding tool. They are suitable for flexible use under rugged conditions and in dry and damp 
rooms as well as permanently outdoors according to HD 516 (Attention: no ozone resistance acc. to HD 22.1 (EM5)). For arc welding, see information 
about current ratings, correction factors and voltage drop in HD 516, please. 
 
PERMISSIBLE VOLTAGES 
(HD 22.1) 
Rated voltage U
0
/U: 
Conductor-to-ground (PE) U
 
100 V AC; 150 V DC 
Conductor-to-conductor (not PE each) U 
100 V AC; 150 V DC 
Operated voltage U
b max
Conductor-to-ground (PE) 
110 V AC; 165 V DC 
Conductor-to-conductor (not PE each) 
110 V AC; 165 V DC 
 
CERTIFICATION 
(HD 22.6) 
Harmonised (◄HAR►) H01N2-D according to the H01N2-D cable type standard in the harmonisation document HD 22.6 
 
CABLE MARKING 
(HD 22.6 & HD 22.1) 
Normative cable type “H01N2-D” according to the H01N2-D cable type standard in the harmonisation document HD 22.6, 
Testing and certification mark “◄HAR►” [empty arrowheads are permitted as well], 
Nominal conductor cross section, 
Other marking parts … 
 
DESIGN   
 
 
(H01N2-D, HD 22.6) 
Conductor  
Soft-annealed electrolyte copper 
 
 
Bare strands  
Conductor class 
Superfine wire strand (IEC 60228/EN 60228, class 6) up to and including 95 mm² 
 
 
From 120 mm²: fine wire strand (IEC 60228/EN 60228, class 5) 
Harmonised nominal cross sections (mm²)  10; 16; 25; 35; 50; 70; 95; 120; 150; 185 
Separation layer 
On each conductor, made of suitable material 
Permissible core quantity 
1X … only 
Sheath 
Extruded, single- or double-layered 
 
Single-layered:  
 
EM5 rubber compound acc. HD 22.1 
 
Double-layered:  
 
Outer layer:  
EM5 rubber compound acc. HD 22.1 
 
 
 
 
Inner layer:  
EM5 or EI7 rubber compound acc. HD 22.1 
Outer cable diameter 
HD 22.6, table 1, columns 4 + 5 
 
ELECTRICAL PROPERTIES AT +20 °C (±10 K) 
Rated voltage U
0
/U 
  100/100 V AC according to HD 22.6 
Test voltage (cable) 
1000 V AC according to HD 22.6, EN 50395 
Max. ohmic conductor DC resistance 
IEC 60228/EN 60228, class 5/class 6; EN 50395; HD 22.6 
 
MECHANICAL, THERMAL AND CHEMICAL PROPERTIES 
Temperature range (HD 516) 
Flexible use:  
 
 
 
-25 °C to +85 °C max. conductor temperature 
 
During installation/maintenance/handling:   
-20 °C min. 
 
Ambient temperature at storing:   
 
+40 °C max. (max. +60 °C at direct solarisation) 
 
Temperature at the cable surface:  
 
+80 °C max. 
Flame retardance (HD 22.6) 
IEC 60332-1-2/EN 60332-1-2 
Oil resistance (EM5 compound, HD 22.1) 
HD 22.1; EN 60811-2-1, 10 
Heat strain (EM5 compound, HD 22.1) 
HD 22.1; EN 60811-2-1, 9 
Weld spatter resistance (HD 22.6) 
EN 50396 (hot pieces test – resistance to hot pieces) 
Kind of mechanical stress (HD 516) 
Heavy (HD 516) 
 
= medium intensity of mechanical stress (HD 516) 
Water resistance (HD 516) 
AD2 (HD 516)  
 
= freely falling water drops 
Resistance to corrosive/polluting 
substances (HD 516) 
AF3 (HD 516)  
 
= accidental or periodic impingement, not permanently 
Mechanical impact stress (HD 516) 
AG2 (HD 516) 
 
= medium intensity 
Vibration stress (HD 516) 
AH3 (HD 516)  
 
= high intensity; significant, industrial workload 
Frequent bending (HD 516) 
Yes (HD 516) 
Frequent torsion (HD 516) 
Yes (HD 516) 
Minimum bending radii (HD 516, table 6c)  Freely movable as well as at the insertion of non-stationary devices and equipment (without mechanical stress 
(further bending factors depending on other 
to the cable): 
general application cases in HD 516, table 6c)
 
D* ≤ 12 mm: 
 
4 x D* 
 
12 mm < D* ≤ 20 mm: 
5 x D* 
 
D* > 20 mm: 
 
6 x D* 
 
If loaded mechanically as well as in case of repetitive spooling events: 
 
D* ≤ 20 mm: 
 
6 x D* 
 
D* > 20 mm: 
 
8 x D* 
Static bending test (HD 22.6) 
HD 22.6, table 4; EN 50396 
No ozone resistance (EM5, HD 22.1) 
No ozone resistance (EM5 acc. HD 22.1) 
Mechanical tests of the sheath (HD 22.6) 
EN 60811 -1-1.9.2/ -1-2.8.1.3.1/ -2-1.10/ -2-1.9 
EC low voltage directive (LVD) 
This cable conforms to 2006/95/EC (European low voltage directive - LVD). 
EC/EU RoHS** directives 
This cable complies with the European RoHS** directives 2002/95/EC and 2011/65/EU. 
 
D* = Outer cable diameter 
RoHS** = 
Restriction of (the use of certain) Hazardous Substances