Lappkabel 0012346, Cable, 3 x 1 mm², Orange Sheath 0012346 Data Sheet

Product codes
0012346
Page of 1
DATA SHEET 
0012345 
 
ÖLFLEX
®
 500 P 
valid from : 
20.07.2009
 
 
 
Originator: R. Krämer / TE-K
 
approved: H. Schillinger / TE-K 
Document: 
DB0012345EN 
page 1 of 1 
All deviations from this specification are subject to explicit consent of U.I.LAPP GmbH. All rights reserved acc. to DIN 34.  
No.: 0019/0408
 
 
Application 
 
ÖLFLEX
®
 500 P  cables are highly flexible oil-resistant connecting cables with an insulation of Polyurethane and 
an  outer  sheath  of  Polyurethane  for  flexible  use  and  fixed  installation  under  increased  mechanical  load  condi-
tions. They are designed for use in dry, damp and wet conditions. Outdoor use: They may only be installed con-
sidering the temperature range. 
Continuous  busy  movements,  compulsory  guidance  respectively  usage  on  cable  drums  or  pulleys  or  under  a 
strain of more than 15 N / mm² are not allowed. At room temperature they are widely resistant to certain oils and 
resistant to acids. The outer sheath of Polyurethane is resistant to high mechanical load, particularly to abrasion 
and scouring, cut resistant, microbe-proof and hydrolysis resistant.  
All materials used for these cables are halogen-free. 
 
 
Design 
 
Design 
based on HD 21.5 S3 resp. VDE 0281-5 
 
Conductor 
superfine wire strands of bare copper  
 
acc. to IEC 60228 resp. VDE 0295, Class 6 
 
Core insulation 
Polyurethane compound 
 
Core identification 
coloured acc. to HD 308 S2 resp. VDE 0293-308 
 
Outer sheath 
Polyurethane compound TMPU in acc. to HD 22.10 S2 resp. VDE 0282-10 
 
colour: Orange 
 
MUD resistant acc. to IEC 61892-4 Annex D 
 
 
 
Electrical properties at 20 °C 
 
Nominal voltage 
300 / 500 V 
 
Test voltage 
3000 V AC 
 
 
Mechanical and thermal properties 
 
Min. bending radius 
occasional flexing:   
15 x cable diameter 
 
 
 
fixed installation: 
  4 x cable diameter 
 
Temperature range 
occasional flexing:   
-40 °C up to +80 °C max. conductor temperature 
 
fixed installation:  
-50 °C up to +80 °C max. conductor temperature 
 
Flammability 
flame retardant in acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2  
 
Oil resistance    
acc. to IEC 60811-2-1 resp. VDE 0473 part 811-2-1 
 
Tests 
acc. to IEC 60811 resp. VDE 0473 and VDE 0472 
 
EC directive 
This cable is conform to ECD 2006/95/EC (Low Voltage Directive).