Lappkabel 0012102, Cable, , Yellow Sheath 0012102 Data Sheet
Product codes
0012102
DATA SHEET
0012101
ÖLFLEX
®
450 P
valid from :
22.02.2006
elaborated by:
TE-K:
Document:
DB0012101EN
page 1 of 1
Nr.: 0019/0894
Application
ÖLFLEX
®
450 P cables are oil resistant PVC-PUR hose cables with an outer sheath of Polyurethane for flexible
use and fixed installation for middle mechanical abuse. They are for use in dry, damp and wet rooms. Under
following of the indicate temperature range is an use outside possible.
Continuous, busy movements, usage of these cables in moving cable carriers, respectively on motor drum
guidance or under a strain of more than 15 N/mm² is not allowed. ÖLFLEX
following of the indicate temperature range is an use outside possible.
Continuous, busy movements, usage of these cables in moving cable carriers, respectively on motor drum
guidance or under a strain of more than 15 N/mm² is not allowed. ÖLFLEX
®
450 P cables are increased oil
resistant and at room temperature generally resistant against acids and caustics solution. The outer sheath is
resistant against high mechanical abuse, particularly to abrasion and grinding abuse. ÖLFLEX
resistant against high mechanical abuse, particularly to abrasion and grinding abuse. ÖLFLEX
®
450 P cables are
resistant against cuts, microbe proof and hydrolysis resistant.
Technical data
Conductor
bare copper, fine wire strand in accordance to IEC 60 228
that is VDE 0295, class 5
Design
in accordance to HD 21.13S1 that is VDE 0281-13 and HD 21.5S3 that is VDE 0281-5
Core insulation
PVC compound TI2 in acc. to VDE 0281 part 1
Identification
colored-coded in acc. to HD 186 that is VDE 0293 or HD308S2 that is
VDE 0293-308
Inner sheath
PVC compound TM2 in acc. to VDE 0281 part 1
Outer sheath:
Polyurethane-compound TMPU in acc. to HD 22.10S1 that is VDE 0282-10
Outer sheath color
yellow (RAL 1016)
Nominal voltage
300/500 V
Test voltage
3000 V AC
Temp. range
for flexible use -5 up to +70° C max. conductor temperature
fixed installation -30 up to +80° C max. conductor temperature
Min. bending radius
flex. use 15 x cable diameter
fixed installation 6 x cable diameter
Flame retardant
in acc. to IEC 60 332.1
Oil resistance
in acc. to VDE 0473 part 811-2-1
Tests
in acc. to VDE 0472 and IEC 60 811-x.x that is VDE 0473
EC directive
this cable confirms to ECD 73/23/EEC (low voltage directive).