5. Handling/Treatment 
 
5.1 Shock Resistance 
In general, Reed Switches provide a high shock resistance of up to 100 
g.  However,  a drop on a hard surface can still  generate a shock of 
several 100 g, which can result in the  de-adjustment of contacts. 
Switches  that have  been dropped should be re-tested for sensitivity 
before usage! 
 
5.2 Do’s and Don’ts when cutting and bending 
 
 
 
 
5.3 Dimensioning of modified Reed Switches 
We supply Reed Switches with terminals that can be modified to 
almost  any requirement. Dimensioning should be made according to 
the examples below.  
 
 
 
__________________________________________________________ 
 
Further Information 
 
Further information about our products, their technical specifications, 
applications and operation as well as information about Magnets are 
available on our website: 
 
http://pic-gmbh.com/en/tech-center/reed-switches/faq/ 
http://pic-gmbh.com/en/catalogue/view-online/ 
 
PIC GmbH 
Nibelungenstr. 5A 
90530 Wendelstein, Germany 
 
Phone   +49 911 995906-0 
Fax 
+49 911 995906-99 
Mail 
info@pic-gmbh.com 
 
 
Facebook.com/picgmbh 
 
© PIC GmbH, 04/2011 
Important Info when testing Reed Switches: 
 
 
Always consider the relevant data sheet, especially 
with regard to the mentioned maximum values. 
 
Always control the coil’s current during the test. 
 
Check the position of the Reed Switch within the 
test coil. A change in position might cause different 
AT measurements. 
 
Consider external magnetic fields: Even the 
earth‘s own magnetic field can result in a variance 
of 1 AT. External magnetic fields could be caused 
by nearby fans, motors etc. 
 
Ferromagnetic materials (e.g. screws) close to the 
test coil can distort the measurements. 
 
Large stresses on the glass tube or the leads 
might result in damage or maladjustments. 
 
Reed Switches are designed to operate under 
specific temperature conditions. Operating under 
higher temperatures than those specified can 
result in an increase of the Pull In value. In 
addition, magnets are temperature-sensitive and 
have a maximum operating temperature. 
 
Reeds and leads are parts of the magnetic circuit. 
Bending and cutting of the leads will cause 
changes in Pull In (PI) and Drop Out (DO) values. 
 
Lifetime/Contact Protection 
 
Lifetime depends on load conditions. If switching signal 
loads only, many millions, and indeed even billions of 
switching cycles can be achieved. Meanwhile, higher 
loads (e.g. mains applications or high currents) may 
provide from 10,000 up to a few million switching 
cycles. Usually the Reed Switch lifetime itself is much 
longer than the lifetime of the device incorporating the 
Reed Switch. As a general rule the same contact 
protection as for common mechanical switches 
(varistors, diodes, RCs) should be provided for Reed 
Switches to prevent the reduction of life expectancy.  
 
Switching of lamp loads: Bulbs with a tungsten filament 
have approximately 10 times less resistance when they 
are cold, as compared to a switched on glowing bulb. 
This means a 10 times higher current occurring during 
the switching process. This current can be reduced by a 
resistor connected in series. Another possibility is the 
parallel connection of a resistor to the switch, in order 
to pre-heat the filament close to the glowing 
temperature. 
 
 Please do not hesitate to contact us if you have any 
questions regarding the test procedure or our 
protocols. We would be happy to help you with any 