Panasonic AQY210KS PhotoMOS Relay AQY210KS Number of pins 4 Pin 1 closure 350 V/DC/AC AQY210KS Data Sheet

Product codes
AQY210KS
Page of 4
GU PhotoMOS (AQY210KS)
4
ds_x615_en_aqy210ks: 181206J
What is short circuit protection latch type?
When the load current exceeds 
specifications, the short circuit protection 
function kicks in and completely cuts off 
the load current, thus turning off the relay.
The short circuit protection inside the 
PhotoMOS relay instantaneously 
(typ. 50 
μs) and completely cuts of the 
load current.
This protects any circuits that follow the 
PhotoMOS relay from excess current.
There is almost no heating of the 
PhotoMOS relay, which prevents it from 
becoming damaged. To restore the 
function of the relay turn off the input 
current and then turn it back on.
In order to operate the short circuit 
protection function, ensure that the input 
current is at least I
F
 = 5 mA.
Output voltage and output current 
characteristics
V-I characteristics of PhotoMOS relay 
with short circuit protection circuit
Output voltage
Output current
Operation chart
Relay input
current
Relay output
current
5mA
120mA
0
0
Detection time
(approx. 50 
µs)
Normal relay operation
Occurrence of
short circuit current
Abnormal current
The short circuit current 
detection device latches 
when the relay is off.
The relay operates normally
when the input current is reset.
If the output section shorts even after 
the input current is reset, it will latch 
when the short circuit current is 
detected again and the relay turns off.