Panasonic Microswitch 30 Vdc 0.5 A 1 x On/(On) AV402461J IP40 momentary 1 pc(s) AV402461J Data Sheet

Product codes
AV402461J
Page of 5
AV4
124
NOTES
Hinge lever type
mm General tolerance: 
±0.15
1.65 dia.
0.8
2.5
0.11
0.6
1.5
1.4
1.4
3.1
3.0
6.5
0.8
1.2
4.0
7.5
4.55
5.1
(F.P.)
9.0 max.
(O.P.)
±0.6
6.4
2.4 max.
(P.T.)
Note: All other dimensions are the same as 
those of pin plunger type.
Pretravel
2.4 max.
Movement Differential
0.7 max.
Overtravel
0.4 min.
Operating Position
6.4
±0.6
Free Position
9.0 max.
Simulated roller lever type
2.5
0.11
0.8
0.6 R
5.5
3.0
2.2 max.
(P.T.)
1.65 dia.
6.7
±0.5
(O.P.)
9.4 max.
(F.P.)
0.7
Note: All other dimensions are the same as 
those of pin plunger type.
Pretravel
2.2 max.
Movement Differential
0.7 max.
Overtravel
0.3 min.
Operating Position
6.7
±0.5
Free Position
9.4 max.
1. Mounting
1) After mounting and wiring, the 
insulation distance between ground and 
each terminal should be confirmed as 
sufficient.
2) When the operation object is in the free 
position, force should not be applied to 
the actuator or to the pin plunger. Also 
force should be applied to the pin plunger 
from vertical direction to the switch.
3) In setting the movement after 
operation, the over-travel should be set 
within the range of the specified O.T. 
value.
4) In fastening the switch body, use the 
M1.4 screw, with tightening torque of not 
more than 0.098 N·m.
2. Soldering
1) Hand soldering should be 
accomplished in less than 5 seconds with 
an iron below 18 watts. Keep the 
soldering tip temperature less than 
320
°C. Avoid applying force to the 
terminals.
2) Terminal portion must not be moved 
within 1 minute after soldering. Also no 
tensile strength of lead wires should be 
applied to the terminals.
3) When using the angle terminal type, 
insert an insulation separator between 
the switch body and the printed circuit 
board (Insulation separator 0.2 to 0.4mm 
thick) to prevent the soldering flux from 
flowing under the PC board.
3. Cleaning
As AV4 switch is not completely sealed 
construction, avoid cleaning.
4. Selection of switch
When specifying AV4 switches, allow 
±20% to the listed operating 
characteristics.
5. Avoid using and keeping switches 
in the following conditions:
• In corrosive gases
• In a dusty environment
• Where silicon atmosphere prevails
6. When switching low-level circuits 
(max. 100 mA), gold plate contact 
types are recommended.
7. When using the lever type, avoid 
applying force from the reverse and 
side direction of actuating.
Switch.book  Seite 124  Donnerstag, 4. Mai 2006  10:05 10