Sanyo PDA rechargeable battery replaces original battery 20-00598-04A WD, 0511-021087, 35-00097-02A 3.7 V 900 mAh 123771 Data Sheet

Product codes
123771
Page of 9
Document NO.: 
WI-FHF-CS-N30SL-A
 
Page 4of 9 
 
MODEL:
 CS-N30SL
 
REV: A/1 
 
 
 
 
 
Notes(
): 
 
 1.  Period of storage is counted from shipping date 
 
2.  
Test Method and standard listed as below, environment temperature (15 25) , CC/CV 
mode, 0.2C constant current charge to 4.2V, then constant voltage charge mode, cut off 
current 0.01C 0.2C constant current discharge, cut off voltage 3.0V more than 5 hours 
discharging time.   
(15 25) ,CC/CV
,0.2C
4.2V,
,
0.01C
0.2C
,
     3.0V
5
 
3.Test (
3.1  Testing Environment
3.1.1 Test time should be no more than one month after receive the battery 
1
 
3.1.2 Testing Environment(
): 
Humidity(
):      15 --25  
Relative Humidity(
):    45%--85% 
Atmospheric Pressure(
):   
76
kPa--106kPa    
 
3.2  Testing Instrument(
): 
3.2.1 Voltage meter 0.5 grade or more regulated by IEC 51/IEC 485, more than 10KΩ/V 
internal resistance     
      
  IEC 51/IEC 485 
0.5
10KΩ/V   
 
3.2.2 Current meter 0.5 grade or more regulated by IEC 51/IEC 485, include wire resistance 
less than 0.01Ω. 
  IEC 51/IEC 485 
0.5
0.01Ω. 
 
3.2.3 Calipers Definition 0.02mm 
  
0.02mm 
 
3.2.4 Internal Resistance Meter    AC 1KHz 4 terminal measure setting. 
  
1KHz 4
 
3.2.5 Load Resistance 
Include external circuitry, allowed resistance figure error is ±5%. 
   
,
±5%. 
 
3.2.6 Finished Battery Product Testing Machine