TP-LINK 16-Port Gigabit Web Smart Switch with 2 Combo SFP Slots TL-SG2216WEB Data Sheet

Product codes
TL-SG2216WEB
Page of 226
 
Parameter 
multiplier —— Configure the Hold Multiplier parameter. It ranges from 2 to 10. 
By default, it is 4. 
Command Mode 
Global Configuration Mode 
Example 
Specify Hold Multiplier as 5: 
TL-SG2424P(config)# lldp hold-multiplier 5 
lldp timer 
Description 
The 
lldp timer  command is used to configure the parameters about 
transmission. To return to the default configuration, please use 
no lldp timer 
command. 
Syntax 
lldp timer { tx-interval tx-interval | tx-delay tx-delay | reinit-delay reinit-delay | 
notify-interval notify-interval | fast-count fast-count } 
no lldp timer { tx-interval | tx-delay | reinit-delay | notify-interval | fast-count } 
Parameter 
tx-interval —— Configure the interval for the local device to transmit LLDPDU to 
its neighbors. The value ranges from 5 to 32768 and the default value is 30 
seconds. 
tx-delay —— Configure a value from 1 to 8192 in seconds to specify the time for 
the local device to transmit LLDPDU to its neighbors after changes occur so as 
to prevent LLDPDU being sent frequently. By default, it is 2 seconds. 
reinit-delay —— This parameter indicates the amount of delay from when LLDP 
status becomes "disable" until re-initialization will be attempted. The value 
ranges from 1 to 10 and the default value is 3. 
notify-interval —— Specify the interval of Trap message which will be sent from 
local device to network management system. The value ranges from 5 to 3600 
and the default value is 5 seconds. 
fast-count  ——  When the port's LLDP state transforms from Disable (or 
Rx_Only) to Tx&Rx (or Tx_Only), the fast start mechanism will be enabled, that 
is, the transmit interval will be shorten to a second, and several LLDPDUs will 
206