12.3.3  Alarm Config 
On this page, you can configure Statistic Group and Alarm Group for RMON. 
Choose the menu 
SNMP→RMON→Alarm Config to load the following page. 
 
Figure 12-11 Alarm Config 
The following entries are displayed on this screen: 
 
Alarm Table 
Select: 
Select the desired entry for configuration. 
Index: 
Displays the index  number of the entry. 
Variable: 
Select the alarm variables from the pull-down list. 
Port: 
Select the port on which the Alarm entry acts.   
Sample Type: 
Specify the sampling method for the selected variable and 
comparing the value against the thresholds. 
 
Absolute: Compares the values directly with the thresholds 
at the end of the sampling interval. 
 
Delta:  Subtracts the last sampled value from the current 
value. The difference in the values is compared to the 
threshold. 
Rising Threshold: 
Enter the rising counter value that triggers the Rising Threshold 
alarm.   
Rising Event: 
Select the index of the corresponding event which will be 
triggered if the sampled value is larger than the Rising 
Threshold.  
Falling Threshold: 
Enter the falling counter value that triggers the Falling Threshold 
alarm. 
Falling Event: 
Select the index of the corresponding event which will be 
triggered if the sampled value is lower than the Falling 
Threshold.  
Alarm Type: 
Specify the type of the alarm. 
 
All:  The alarm event will be triggered either the sampled 
value exceeds the Rising Threshold or is under the Falling 
Threshold. 