Grandstream HT701 HANDYTONE ATA-ROUTER HT701 User Manual

Product codes
HT701
Page of 51
 
 
FIRMWARE VERSION 1.0.4.14                                  HT70X USER MANUAL                                     Page 48 of 51  
 
End  users  can  also  choose  to  download  the  free  HTTP  server  from  http://httpd.apache.org/  or  use 
Microsoft IIS web server. 
CONFIGURATION FILE DOWNLOAD
 
Grandstream SIP Device can  be  configured  via  Web Interface  as  well as  via  Configuration File through 
TFTP or HTTP/HTTPS
. “Config Server Path” is the TFTP or HTTP/HTTPS server path for configuration 
file. It needs to be set to a valid URL, either in FQDN or IP address format. The “Config Server Path” can 
be same or different from the “Firmware Server Path”. 
 
A  configuration  parameter  is  associated  with  each  particular  field  in  the  web  configuration  page.    A 
parameter  consists  of  a  Capital  letter  P  and  1  to  3  (Could  be  extended  to  4  in  the  future)  digit  numeric 
numbers.    i.e.,  P2  is  associated  with  “Admin  Password”  in  the  ADVANCED  SETTINGS  page.    For  a 
detailed parameter list, please refer to the corresponding firmware release configuration template. 
  
When  a  Grandstream  device  boots  up  or  reboots,  it  will  issue  a  request  for  a  configuration  file 
“cfgxxxxxxxxxxxx”, where “xxxxxxxxxxxx” is the MAC address of the device, i.e., “cfg000b820102ab”.  In 
addition,  device  will  also  requests  a  XML  configuration  file  “cfgxxxxxxxxxxxx.xml”.  If  the  download  of 
“cfgxxxxxxxxxxxx.xml”  is  not  successful,  the  provision  program  will  issue  a  request  for  a  generic 
configuration  file  “cfg.xml”.  Configurat ion  file  name  should  be  in  lower  case  letters. 
 
For more details on XML provisioning, please refer to: 
  
 
FIRMWARE AND CONFIGURATION FILE PREFIX AND POSTFIX 
Firmware Prefix and Postfix allows device to download the firmware name with the matching Prefix and 
Postfix.    This  makes  it  the  possible  to  store  ALL  of  the  firmware  with  different  version  in  one  single 
directory.  Similarly, Config File Prefix and Postfix allows device to download the configuration file with the 
matching  Prefix  and  Postfix.  Thus  multiple  configuration  files  for  the  same  device  can  be  stored  in  one 
directory. 
 
In addition, when  the field 
“Check New Firmware only when F/W pre/suffix changes” is set to “Yes”, the 
device will only issue firmware upgrade request if there are changes in  the firmware Prefix or Postfix. 
 
 
MANAGING FIRMWARE AND CONFIGURATION FILE DOWNLOAD  
When “Automatic Upgrade” is set “Yes, every” the auto check will be done in the minute specified in this 
field. If set to “daily  at  hour  (0-23)”, Service Provider can use P193 (Auto Check Interval) to have the