Arnold Rak 70 m Heating Cable / 16-070-F Data Sheet

Product codes
16-070-F
Page of 2
 
Installation Instructions 
 
Heating Cables 
 
Product information 
 
 
The heating cables are resistance heating cables to DIN VDE 0253 and are supplied ready for connection. 
They  are  suitable for  a wide  range  of  applications,  including  heating  terrariums,  cold frames,  greenhouses, 
young animal breeding stations or foundations of cold-storage warehouses. 
The  heating  cable  with  frost  protection  function  is  specially  designed  as  a  pipeline  heating  system  and  is 
automatically turned on at a temperature of less than 5° C. 
 
The  heating  cable  with  a  voltage  of  12  V  is  designed  as  a  flexible,  open-ended  connection  cable  and  is 
suitable  for  use  in  e.g.  vehicles,  caravan  or  boat  building  or  specifically  for  greenhouses  with  a  12  V  solar 
system. 
 
Type 
Rated 
voltage 
Frost protection 
function 
Connection 
Minimum bending 
radius 
Max. surface 
temperature 
HK-xxx-F 
230 V 
yes 
Safety contact 
plug, VDE 
1.5 cm 
 
105° C 
HK-xxx 
230 V 
no 
Safety contact 
plug, VDE 
1.5 cm 
 
105° C 
HK-xxx-12 
12 V 
no 
without plug 
1.5 cm 
 
200° C 
 
Important Information / Technical Notes 
 
Please be sure to observe the following precautions before installing the heating cable: 
 
  Carefully read these instructions before commencing installation work. 
 
 
The  heating  cable  must  only  be  connected  to  the  specified  power  supply.  Modifications  of  length, 
power or voltage are not permitted.
 
 
  A circuit breaker (RCB < 30 mA) must be used as a precaution. 
 
 
The  manufacturer  grants  a  2-year  warranty.  Damages  caused  by  the  non-observance  of  the 
instructions  void  the  warranty.  The  manufacturer  accepts  no  liability  for  consequential  damages 
thereof. Please make sure to retain the warranty card.
 
 
  The  manufacturer  cannot  be  held  responsible  for  errors  that  are  attributable  to  the  omission  of  or 
erroneous measurements. 
 
 
The  location  of  the  heating  cable  is  to  be  documented  on  the  attached  warranty  card  –  a  sketch  is 
sufficient. 
 
 
Heating  cables  must  not  be  used  as  a  loose  heating  element.  They  must  always  be  installed  as  a 
fixed component and fully protected against damages.
 
 
     Damages  of  the  heating  cables  are  to  be  avoided  (no  compression,  folding  or  tensile  load  on  the 
heating cable and connection socket). They must not be routed across sharp-edged or sharp objects.
 
 
     Heating  cables  must  not  be  shortened  or  connected  directly.  Only  the  connection  cable  may  be 
shortened and connected.  
 
 
     The heating cables must not touch or cross each other.  
 
     Heating  cables  must  not  be  routed  across  expansion  joints.  In  these  locations,  the  heating  cables 
must be protected by two moveable pipes, one inserted into the other.
 
    
 
     Do not install the heating cables in temperatures below +5° C. 
 
     Do  not  route  the  heating  cables  through  walls,  timber  constructions,  roof  conduits  and  insulating 
material as this would prevent heat distribution. 
 
     The heating cable must not be accessible to people or animals. 
 
     Do not bend the heating cables with a radius of less than 1.5 cm. 
 
     The maximum rated temperature must not be exceeded when installing the cable. 
     
 