Suevia DIN rail mount timer digital Data Log I 230 Vac 16 A/250 V Data Log I Data Sheet

Product codes
Data Log I
Page of 2
DIMENSIONS
LANGUAGE SELECTION
PROGRAMMING  ON: Monday 09:10   OFF: Tuesday 11:30
PROGRAMMING  CYCLE. START DAY: Monday 09:00.  END DAY: Friday 18:00. ON: 2h  OFF: 5h.
CLOCK SETTING
Monday 9:00 h
2h20min. OFF
Time ON
Time OFF
Begin day
Day end
Time OFF
Friday 13:00 h
Time ON
TECHNICAL FEATURES
Power supply:
As indicated on the device
Switching capacity:
16 (10)A/250V
Maximum recomended loads:
Incandescent lamps.
3000 W.
Uncompensated fluorescent lamps. 1200 W.
Compensated fluorescent lamps.
1200 W. 150 µF
Low- voltage halogen lamps.
1000 VA.
Halogens (230 V.). 
2500 W.
Low-consumption lamps-
10X23 W.
Contact type and material:
Changeover AgSnO
2
Power consumption:
6 VA  1 circuit (approx.1 W)
Number of programs:
50
Type of programs:
ON OFF
PULSE (1 to 59 seconds)
CYCLES (from 1 minute to 23hours 
59 minutes, in ON or OFF times)
Switching accuracy:
Better than 1 second
Operating accuracy:
≤ ± 1s/day at 23ºC
Reserve battery: 
5 years. (Lithium Battery)
Working temperature:
-10 ºC to +45 ºC
Protection type:
IP 20 according to EN 60529
Protection class:
II according to EN 60335 when 
mounting as intended
display. Press “OK “ again and the display will show CLEAR  C1  YES.
Use 
∆ and ∇ to choose between YES and NO and confirm pressing
“OK “. Press the “ C “ key repeatedly to go back to normal operating
mode.
12 (AM – PM) or  24-HOUR TIME MODE
You can choose between the time being displayed in AM : PM or 24-
hour format. In normal operating mode, press “OK “ and use 
∆ and ∇  to
find EXTRAS 12/24H. From this menu, choose 12H or 24H and confirm
with “OK “. Press the “ C “ key repeatedly to return to normal operating
mode. If the 12h function has been chosen, AM or PM will be shown on
display, depending on the current time.
CYCLE PROGRAMMING
A cycle is a sequence of repetitive switches. 
Each programmed cycle takes up two memory spaces (PROG X,
PROG X+1). Go into the MENU PROGRAM and press “OK “. Use the
∆ and ∇  keys to choose a program (PROG XX), press “OK“ again and
PROG (XX) PROGRAM will be displayed. Confirm with “OK “ and
C1:ON will be displayed. Select CYCLE, press “OK “, and you will see
DAY BEG MO: YES (to allow you to select the starting day for the
cycle). If you want it to begin on Monday, press “OK “, otherwise use the
∆ and ∇  keys until DAY BEG MO: NO appears on the display. Press
“OK “ to accept and repeat the operation for the other days of the week,
selecting and confirming them in the same way.
When you have chosen the days, you need to select the start time for
the cycle, beginning with the hour. Use the 
∆ and ∇  keys to enter the
hour and confirm with “OK “. Enter the cycle start minutes in the same
way, and when you confirm “OK “, DAY END MO: YES (to allow you to
select the last day for the cycle) will be displayed. Repeat the same pro-
cedure to enter the days, hours and minutes for conclusion of the cycle.
Next, the cycle connection time (TIME ON ) needs to be programmed.
Enter the figures for hours and minutes (maximum 23 hours 59 minu-
tes.- minimum 0 hour 1 minute) and then the cycle disconnection time
(TIME OFF) in hours and minutes (maximum 23 hours 59 minutes.-
minimum 0 hour 1 minute). (See exemple ) 
Before programming, check that the next memory program is free.  It is
it not free, option CYCLE will not then be available. CYCLE programs
are not permited in memory program 50. Do not program averlaped
cycles, as during the execution of one cycle, the overlaped cycle will not
start.
Cycles are shown in chronogram as ON from begining to the end.
A016.17.51742
Septiembre, 2002
Suevia Zeitschalttechnick GmbH
Robert-Bosch-Str. 3
D-71088 Holzgerlingen
Telefon 0 70 31 / 86 65-0
Telefax
0 70 31 / 86 65-10