Pizzato Elettrica VF AF-KT20M0 Accessory Set For FD Cable Emergency Switch Accessory set VF AF-KT20M0 Data Sheet
Product codes
VF AF-KT20M0
Technical data
© 2005 Cop
yr
ight Pizzato Elettr
ica
General Catalog 18
page
4/69
4
General Catalog 18
page
4/70
© 2005 Cop
yr
ight Pizzato Elettr
ica
4
Rope safety switches with reset
for emergency stop
General data
Ambient temperature:
Ambient temperature:
from -25°C to +80°C
Version for operation in ambient temperature from -40°C to +80° C on request
Max operating frequency:
1 operation cycles / 6 s
Mechanical endurance:
1 million of operations cycles
1
Max actuating speed:
0,5 m/s
Min. actuating speed:
1 mm/s
(1) One operation cycle means two movements, one to close and one to open contacts, as foreseen by IEC 947-5-1
standard.
standard.
Cross section of the conductors (flexible copper wire)
Contact blocks
Contact blocks
20, 21, 22, 33, 34:
min.
1 x 0,34 mm
2
(1 x AWG 22)
max.
2 x 1,5 mm
2
(2 x AWG 16)
Contact blocks
18, 9:
min.
1 x 0,5 mm
2
(1 x AWG 20)
max.
2 x 2,5 mm
2
(2 x AWG 14)
Markings and quality marks:
Approval IMQ:
EG605
(FD-FL-FC series)
EG606
(FP series)
Approval UL:
E131787
Approval EZU:
1010151
Electrical data
Utilization categories
Alternate current: AC15 (50...60 Hz)
Ue (V)
Ue (V)
250
400
500
Ie (A)
6
4
1
Direct current: DC13
Ue (V)
Ue (V)
24
125
250
Ie (A)
6
1,1
0,4
Alternate current: AC15 (50...60 Hz)
Ue (V)
Ue (V)
24
120
250
Ie (A)
4
4
4
Direct current: DC13
Ue (V)
Ue (V)
24
125
250
Ie (A)
4
1,1
0,4
Thermal current (Ith):
4 A
Rated insulation voltage (Ui):
250 VAC 300 VDC
Protection against short circuits:
fuse 4 A 500 V type gG
Pollution degrees:
3
with 4 or 5 poles
M12 connector
Thermal current (Ith):
2 A
Rated insulation voltage (Ui):
30 VAC 36 VDC
Protection against short circuits:
fuse 2 A 500 V type gG
Pollution degrees:
3
with 8 poles
M12 connector
Alternate current: AC15 (50...60 Hz)
Ue (V)
Ue (V)
24
Ie (A)
2
Direct current: DC13
Ue (V)
Ue (V)
24
Ie (A)
2
Thermal current (Ith):
10 A
Rated insulation voltage (Ui):
500 VAC 600 VDC
400 VAC
for contact blocks 20, 21, 22, 33, 34
Protection against short circuits:
fuse 10 A 500 V type aM
Pollution degrees:
3
without
connector
Main data
Metal or polymer housing, from one to
three conduit entries
Protection degree IP67
In conformity with EN 418
7 contact blocks available
Transversal head or longitudinal head
In conformity with EN 418
7 contact blocks available
Transversal head or longitudinal head
versions
M12 assembled connector versions
Silver contacts gold plated versions
Several accessories available
Silver contacts gold plated versions
Several accessories available
Housing
Housing type FP made of glass-reinforced polymer, self-extinguishing, shock-
proof thermoplastic resin with double insulation
Housing type FD and FC made of metal, coated with baked epoxy powder.
Housing type FP made of glass-reinforced polymer, self-extinguishing, shock-
proof thermoplastic resin with double insulation
Housing type FD and FC made of metal, coated with baked epoxy powder.
FD, FP and FC series one conduit entry
FL series three conduit entries
Protection degree:
FL series three conduit entries
Protection degree:
IP67
In conformity with standards:
IEC 947-5-1, IEC 337-1, EN 60947-5-1, CEI EN 60947-5-1, CEI 17-45, EN 1088,
EN ISO 12100-1, EN ISO 12100-2, EN 418, NFC 63-140, VDE 0660-200, VDE
0113, CENELEC EN 50013.
IEC 947-5-1, IEC 337-1, EN 60947-5-1, CEI EN 60947-5-1, CEI 17-45, EN 1088,
EN ISO 12100-1, EN ISO 12100-2, EN 418, NFC 63-140, VDE 0660-200, VDE
0113, CENELEC EN 50013.
Approvals:
IEC 947-5-1, UL 508.
IEC 947-5-1, UL 508.
In conformity with requirements requested by:
Low Voltage Directive 73/23/EEC and subsequent modifications and completions.
Machinery Directive 98/37/EEC.
Electromagnetic Compatibility 89/336/EEC and subsequent modifications and
completions.
Low Voltage Directive 73/23/EEC and subsequent modifications and completions.
Machinery Directive 98/37/EEC.
Electromagnetic Compatibility 89/336/EEC and subsequent modifications and
completions.
Positive contact opening in conformity with standards:
IEC 947-5-1, EN 60947-5-1, CEI EN 60947-5-1, VDE 0660-206.
IEC 947-5-1, EN 60947-5-1, CEI EN 60947-5-1, VDE 0660-206.
For the correct installation of all articles, please see “Utilization requirements” chapter, from page 6/1 to page 6/4.