Pizzato Elettrica VF AF-KT20M0 Accessory Set For FD Cable Emergency Switch Accessory set VF AF-KT20M0 Data Sheet

Product codes
VF AF-KT20M0
Page of 8
Technical data
© 2005 Cop
yr
ight Pizzato Elettr
ica
General Catalog 18
page 
4/69
4
General Catalog 18
page 
4/70
© 2005 Cop
yr
ight Pizzato Elettr
ica
4
Rope safety switches with reset 
for emergency stop
General data
Ambient temperature:  
from -25°C to +80°C
Version for operation in ambient temperature from -40°C to +80° C on request
Max operating frequency:  
1 operation cycles / 6 s
Mechanical endurance:  
1 million of operations cycles
1
Max actuating speed: 
0,5 m/s
Min. actuating speed: 
1 mm/s
(1) One operation cycle  means two movements, one to close and one to open contacts, as foreseen by IEC 947-5-1 
standard.
Cross section of the conductors (flexible copper wire)
Contact blocks 
20, 21, 22, 33, 34: 
min. 
1 x 0,34 mm
2
 
(1 x AWG 22)
 
 
max.
  2 x 1,5 mm
2
  
(2 x AWG 16)
Contact blocks
 18, 9:
 
min.
  1 x 0,5 mm
2
  
(1 x AWG 20)
 
max.
  2 x 2,5 mm
2
  
(2 x AWG 14)
Markings and quality marks:
Approval IMQ:
 
EG605
 
(FD-FL-FC  series)
 
EG606
 
(FP series)
Approval UL:
 
E131787
Approval EZU: 
1010151
Electrical data
Utilization categories
Alternate current: AC15 (50...60 Hz)
Ue (V) 
250 
400 
500
Ie (A) 
1
Direct current: DC13
Ue (V) 
24 
125 
250
Ie (A) 
1,1 
0,4
Alternate current: AC15 (50...60 Hz)
Ue (V) 
24 
120 
250
Ie (A) 
4
Direct current: DC13
Ue (V) 
24 
125 
250
Ie (A) 
1,1 
0,4
Thermal current (Ith):  
4 A
Rated insulation voltage (Ui):  
250 VAC 300 VDC
Protection against short circuits:  
fuse 4 A  500 V type gG
Pollution degrees:  
3
with 4 or 5 poles
M12 connector
Thermal current (Ith):  
2 A
Rated insulation voltage (Ui):  
30 VAC 36 VDC
Protection against short circuits:  
fuse 2 A  500 V type gG
Pollution degrees:  
3
with 8 poles
M12 connector
Alternate current: AC15 (50...60 Hz)
Ue (V) 
24         
Ie (A) 
  
Direct current: DC13
Ue (V) 
24  
Ie (A) 
2  
Thermal current (Ith):  
10 A
Rated insulation voltage (Ui):  
500 VAC 600 VDC
 
400 VAC 
for contact blocks 20, 21, 22, 33, 34
 
Protection against short circuits:  
fuse 10 A  500 V type aM
Pollution degrees:  
3
without
connector
Main data
 Metal or polymer housing, from one to 
three conduit entries
 Protection degree IP67
 In conformity with EN 418
 7 contact blocks available
 Transversal head or longitudinal head 
versions
 M12 assembled connector versions
 Silver contacts gold plated versions
 Several accessories available
Housing
Housing type FP made of glass-reinforced polymer, self-extinguishing, shock-
proof thermoplastic resin with double insulation 
Housing type FD and FC made of metal, coated with baked epoxy powder.
FD, FP and FC series one conduit entry
FL series three conduit entries
Protection degree:  
IP67 
In conformity with standards:
IEC 947-5-1, IEC 337-1, EN 60947-5-1, CEI EN 60947-5-1, CEI 17-45, EN 1088, 
EN ISO 12100-1, EN ISO 12100-2, EN 418, NFC 63-140, VDE 0660-200, VDE 
0113, CENELEC EN 50013.
Approvals:
IEC 947-5-1, UL 508.
In conformity with requirements requested by: 
Low Voltage Directive 73/23/EEC and subsequent modifications and completions. 
Machinery Directive 98/37/EEC.
Electromagnetic  Compatibility  89/336/EEC  and  subsequent  modifications  and 
completions.
Positive contact opening in conformity with standards: 
IEC 947-5-1, EN 60947-5-1, CEI EN 60947-5-1, VDE 0660-206.
 For the correct installation of all articles, please see “Utilization requirements” chapter, from page 6/1 to page 6/4.