Schlegel Emergency-off Minibox MBM128_NOOM MBM128_NOOM Leaflet

Product codes
MBM128_NOOM
Page of 2
*
1) M12  versions 
*2) NH
 
 
Georg Schlegel GmbH & Co. KG - D-88525 Dürmentingen - Tel.: 0 73 71 / 502 - 0 - Fax: 0 73 71 / 502 - 49 - info@schlegel.biz - www.schlegel.biz 
Seite 1 /1 
 
Minibox - 
Operating Instructions
 
(Translation of the Original Instructions) 
ba_e_minibox_6154031_v11_130426.doc
V11, 26.04.2013
 
Ref. No.: 6154031 
- All rights reserved -
- The herein specified product properties and technical data do not represent any warranty - 
1 About 
Safety 
  
1.1       Safety Regulations: These operating and mounting 
instructions must be provided to the person who installs the Minibox 
with emergency stop/switch-off device. Please read them carefully 
and keep them for future reference. 
 
1.2  Application: The Schlegel emergency-stop Minibox is a 
electromechanical switchgear serving to protect persons working 
with machinery or close to it. It is used to stop or switch off 
machinery and equipments in order to avert impending or minimise 
existing dangers to persons or damages on machines /material. 
 
The following (inter)national statutory provisions apply to installation, 
commissioning and regular technical inspections: 
 
- Directive 2006/42/EG 
 
- Low-Voltage Directive 2006/95/EG 
 
- Safety Regulations as well as 
 
- Regulations of the Accident Prevention / Safety Rules. 
 
Manufacturers and operators of machines using E-stops or 
emergency switch-off devices should retain the responsibility for the 
adherence of these instructions as well as for compliance with the 
relevant Safety Regulations and Rules. 
For the application of E-stops /emergency switch-off devices as 
directed the respective requirements for installation and operation 
must be observed: 
 - 
EN60204-1:2006 
 - 
EN13849-1/-2:2008 
 
- EN ISO 13850:2008 
 
    Disconnect equipment and device from the mains before 
     installation! 
    E-stops/ emergency switch-off devices fulfil the function of 
personal protection. Improper installation or unauthorised 
modification may lead to severe personal injuries! 
    E-stops /emergency switch-off devices should not be bypassed, 
removed or otherwise disabled! 
(!)   Improper installation or tampering may result in machine and 
material damages! 
(!)   The E-stop / emergency switch-off function should not replace 
the applicable safety precautions or other safety functions but 
should rather be used as a back-up safeguarding measure.  
(!)   The E-stop /emergency switch-off function should not impair the 
effectiveness of other safety devices or equipment with other 
safety functions. 
(!)  Based on his hazard analysis the design engineer must ensure 
that in combination with the control system the E-stop 
/emergency switch-off device meets the required safety 
category. 
 
1.3 
Technical Data and Connection:  
see Wiring Instructions, ref. no.: 6154030 or data sheet *
1) 
   
6154033-00/-10/-20/-30/-40/-50 
2   Product Description 
2.1 Construction: The emergency-stop minibox has been designed for 
cable entries M16 (lateral) and M20 ( bottom-side) as well as for M12 
connection. An illuminated version of the E-stop button is optionally 
available. The button is actuated by pushing and reset by turning into 
both directions. 
 
 
 2.2 
Product References:
 
3  Assembly and Commissioning 
  See Mounting / Wiring Instructions, ref.nos.: 615032/6154030 
    or data sheet 
*1
) 6154033-00/-10/-20/-30/-40/-50 
   
3.1   Notes  
  1) A "click" must be heard when closing the box. 
     (!) Check whether the two Minibox parts are snapped together properly. 
 
 Make sure that the E-stop is always easily accessible.  
 
4  Testing Before First Operation: 
 Mechanical 
Test: 
E-stop/switch-off device latches when operated. 
  Electrical Test: Machine stops / switches off. 
 
5  Regular Technical Inspection 
- Based on his risk assessment, the machine designer has to 
 determine the inspection interval. It is, however, recommended  
 that the competent safety officer activates and tests the E-stop  
 or switch-off device at least once a year to ensure its proper  
 functioning. 
- Mechanical and electrical functional testing acc. to paragraph 4 
- Secure mounting 
- No visible unauthorised modifications or damages 
- No loose connections 
6 Dismounting 
 
      Before dismounting disconnect equipment and device from the  
      mains!! 
7 Incident 
Management: 
      Mechanical overload or external impact damage may impair the  
      function of the E-stop / switch-off device. Make functional tests as 
      mentioned under paragraph 5. 
8  EC Declaration of Conformity: 
 
Name/address of issuer:
Georg Schlegel GmbH & Co. KG,
 
88525 Dürmentingen, Kapellenweg 4, 
Responsible for documentation: 
T.Gairing,Georg Schlegel GmbH&Co.KG  
 
Kapellenweg 4, 88525 Dürmentingen 
Product description 
Minibox with E-stop /switch-off device 
Type references: 
refer to above table 2.1 
The specified products comply with the provisions of the following directives: 
Directive: of:  applied 
norms: 
 
2006/95/EG  
12.12.2006 
EN 60947-5-1:2004,  
 
  
EN 
60947-5-5:1997+A1:2005 
2006/42/EG  
17.05.2006 
EN 60947-5-5:1997+A1:2005 
 
 
EN ISO 13850:2008 
 
Ref. No.
Connection 
Ag /Au 
8
*2)
MBP_FRVKOO
cable entry 
M16     lateral 
Ag
MBP_FRVKOO_AU
Au
MBP_FRVKLOO
Ag

MBP_FRVKLOO_AU
Au

MBW_FRVKOO
cable entry 
M20   bottom-
side 
Ag
MBW_FRVKOO_AU
Au
MBW_FRVKLOO
Ag

MBW_FRVKLOO_AU
Au

MBM124_FRVKOO
M12 
Ag
MBM128_FRVKOOI
Au
MBM128_FRVKLOO
Au

MBM125_FRVKOO
Au
MBM128_NOOITI
Au
MBM128_NOOTLI
Au

MBM128_NOOM