Panasonic Limit switch 115 Vdc, 250 Vac 5 A Spring-loaded rod momentary AZ8107CEJ IP64 1 pc(s) AZ8107CEJ Data Sheet

Product codes
AZ8107CEJ
Page of 8
36
SPECIFICATIONS
1. Rating
1) Standard type
Load  
Rated control voltage
Resistive load
(cos 
φ]1)
Inductive load
(cos 
φ]0.4)
5A
125V AC
3A
5A
250V AC
2A
0.4A
125V DC
0.1A
2) Type with indicator
Types
Rated control
voltage
Resistive load
(cos 
φ]1)
Inductive load
(cos 
φ]0.4)
With Neon lamp
With LED
125V AC
5A
3A
240V AC
5A
2A
24V DC
3A
2. Characteristics
1 Form Z
In the free position
Contact arrangement
3. EN60947-5-1 performance
4. Operating characteristics
Item
Rated insulation voltage (Ui)
Rated impulse withstand voltage (Uimp)
Switching overvoltage
Rated enclosed thermal current (Ithe)
Conditional short-circuit current
Short-circuit protection device
Protective construction
Pollution degree
Rating
250VAC
2.5kV
2.5kV
5A
100A
10A fuse
IP64
3
15mΩ (By voltage drop 6 to 8V DC at rated current)
Initial contact resistance, max.
Gold clad over silver
Contact material
Min. 100MΩ
Initial insulation resistance (At 500V DC)
1,000Vrms for 1 min  Between non-consecutive terminals 2,000Vrms for 1 min  Between
dead metal parts and each terminal 2,000Vrms for 1 min Between ground and each terminal
Initial breakdown voltage
Max. 98m/s
2
{10G}
In the full operating position
Max. 294m/s
2
{30G}
Vibration resistance
Standard type: Max. 55Hz   Type with indicator: 10 to 50Hz, double amplitude of 1.5mm
10
7
(at 120 cpm)
Shock resistance max.
Mechanical
3
10
5
(at rated resistive load) 5
10
6
(Magnetic contactor FC-100 200V AC load)
Electrical
Min. 2
10
4
hours (Neon lamp type)
Life of lamp
–20 to +60°C 
–4 to +140°F
/Max. 95%
Ambient temperature/Ambient humidity
120 cpm
Max. operating speed
Expected life (Min. operations)
Characteristics
Actuator
Totaltravel (T.T.), min.
mm 
inch
Overtravel (O.T.), min.
mm
inch
Movement Differential
(M.D.), max. mm
inch
Pretravel (P.T.), max.
mm 
inch
R.F. (N {gf}) min.
O.F. (N {gf}) max.
1.47 {150}
8.83 {900}
5.88 {600}
0.49 {50}
20°
10°
75°
95°
1.5 
.059
0.7 
.028
.028
5.5 
.217
Push plunger
Roller plunger
Cross roller plunger
Roller arm
7.84 {800}~3.35 {342}
0.49 {50}~0.21 {21}
20°
10°
75°
95°
Adjustable roller arm
7.84 {800}~1.99 {203}
0.49 {50}~0.12 {12}
20°
10°
75°
95°
Adjustable rod
0.88 {90}
30 (1.181)
20 (
.787
)
50 (
1.969
)
Flexible spring wire
19.61 {2,000}~
24.52 {2,500}*
1.96 {200}~
1.96 {200}*
1.5 
.059
.157
*
0.7 
.028
2.0 
.079
*
4.5
.177
2.0 
.079
*
.236
.236
*
Remote wire control
plunger
*Characteristics measured at bent condition: min. radius 100mm 
3.937inch
.
Notes 1. Keep the total travel values in the specified range. Otherwise the actuator force may rise to several times the operating force, resulting in a mechanical failure or much shorter service life.
2. For the operating characteristics, refer to the TECHNICAL INFORMATION.
Protective construction
IEC
VL mini limit SW
VL mini limit SW
(with indicator)
IP60
IP64




5. Protective construction
Types
Rated operating voltage Operating voltage range
Internal resister
100 to 200V AC
80 to 240V AC
120kΩ
6V DC
5 to 15V DC
2.4kΩ
12V DC
9 to 28V DC
4.7kΩ
24 to 48V DC
20 to 55V DC
15kΩ
Neon lamp
LED
6.Lamp rating
DATA
1. Life curve
200
30
0
100
Load current, A
300
400
500
1000
Life curve, resistive load
(AC 240VC cos   =1)
5
10
No. of operating
million times
φ
2. Actual load life curve (relay coil load)
Various relay loads (VA)
VC-20
0
0.5
NK
3
HP
1.0
HC
HG
5
500
1000
260
FC-35
50
FC-10
FC-100
700
No. of operating
million times
WIRING DIAGRAM
Output circuit
Terminal
12
11
NC
NC
VL
14
13
NO
NO
12
14
11
13
Note: The FC magnetic contactor series is 200V AC. The K is
2 Form C 24V DC type.
VL (AZ8)
04/2005