Siku Ventilation technology 125 ST Silenta fan White 30384 User Manual

Product codes
30384
Page of 18
11
The exhaust fans type SIKU 100/120/150 are recommended for gravitational ventilation in 
compartments with individual ventilation ducts. The minimum diameter of the ventilation duct should be 
100/120/150 mm. The fansare equipped with silent electric motor. The fan is made of high quality 
ABC plastic. It enables the disposal of smoke, humidity, and disagreeable odorwithin a short period of 
time. The fans are produced in 12 versions.
INSTRUCTION MANUAL (EN)
Assignment
Installation
The ventilation fans are to be installed in the inlet of the ventilation duct. To attach the fans, please take off the front 
cover by levering with a screwdriver from the bottom. Next insert the fan into a duct and mark the points on the wall 
for the four screws. Place the fan in the inlet and put the outer cover on the body of the fan, beginning from the 
upper side and then press hard. The fans with the time switch are programmable from two to thirty minutes. It 
means that after the fan was switched manually, it will switch off automatically after the time programmed earlier.
The time of operation is set for two minutes.
Remarks
Assembly, disassembly and maintenance are to be performed after the power supply has been cut off. Do not 
change the cylindrical part of the fan while installing. It will allow for the constant operation of the fan. After the fan 
has been switched off, it will continue operation for the period set with the potentiometer. In case of damages, any 
repairs are to be performed by qualified specialists.
Operation recommendations
In case of fouling, please clean the fan. Disconnect it from the mains and next disassembly the item by levering off 
the coyer case with a screwdriver from the bottom. Clean all plastic details, using warm water with addition of the 
washing agents. Before the reassembly, dry all plastic elements. Do not use petrol or dissolvent.
Terms of guarantee
1. A producer guarantees good quality and correct operation of the equipment for which the above guarantee has 
been in the period of 12 months since the date of sale.
2. Any faults or damages during the period of the guarantee will be removed free of charge within 21 days since
 the delivery of the damaged equipment to the service place.
3. The notices on faults will be examined by the service centers. In case of lack of such service centers, any 
notices will be examined by the sellers or by the producer.
4. The notion “repair” does not include any activities predicted by the producer as to be executed by the user, e.g. 
current maintenance. 
5. In case of loss of the guarantee card, no duplicate will be issued.
6. The guarantee does not include any damages resulting from improper use, storing, maintenance or willful 
tearing of the seals as well as mechanical damages.
SIKU 1
SIKU 100 S
SIKU 100 PF
SIKU 100 AZ
SIKU 125 Turb
220-240 V
 
220-240 V
 
220-240 V
 
220-240 V
 
220-240 V
 
220-240 V
 
SIKU 2
SIKU 3
220-240 V
 
SIKU 125 S
SIKU 125 PF
SIKU 125 AZ
SIKU 100 M
SIKU 125 M
220-240 V
 
220-240 V
 
220-240 V
 
220-240 V
 
220-240 V
 
14 W
16 W
24 W
14 W
14 W
20 W
20 W
16 W
16 W
16 W
22 W
14 W
3
180 m /h
3
105 m /h
3
188 m /h
3
298 m /h
3
95 m /h
3
98 m /h
3
98 m /h
3
185 m /h
3
185 m /h
3
232 m /h
3
98 m /h
3
185 m /h
II IPX4
II IPX4
II IPX4
II IPX4
II IPX4
II IPX4
II IPX4
II IPX4
II IPX4
II IPX4
II IPX4
II IPX4
Rating voltage
(50 Hz)
Power
Air flow
Isolation class 
(no earthing)
Operation
 
S1 
(constant operation)
 
S1 
(constant operation)
 
S1 
(constant operation)
 
S1 
(constant operation)
 
S1 
(constant operation)
 
S1 
(constant operation)
 
S1 
(constant operation)
 
S1 
(constant operation)
 
S1 
(constant operation)
 
S1 
(constant operation)
 
S1 
(constant operation)
 
S1 
(constant operation)
Technical