Tracopower TXL 035-05S 35W Enclosed Power Supply 5Vdc 7A TXL 035-05S Data Sheet
Product codes
TXL 035-05S
http://www.tracopower.com
Page 3 of 10
Enclosed Power Supplies
TXL Series
15–1000 Watt
Input Specifications
Input voltage range
– nominal
100 – 240 VAC
– AC range (universal input)
85 – 264 VAC for 15 to 300 Watt model
85 – 264 VAC for 600 & 100 Watt models
– DC range
120 – 375 VDC or 15 to 300 Watt model
127 – 375 VDC for 600 & 100 Watt models
Input current (at full load)
Vin = 115 VAC
Vin = 230 VAC
TXL 015/025 models 0.50 A typ.
0.22 A typ.
TXL 035 models 0.70 A typ.
0.42 A typ.
TXL 060 / 070 models 1.00 A typ.
0.60 A typ.
TXL 100 models 1.65 A typ.
0.95 A typ.
TXL 120 models 1.30 A typ.
0.65 A typ
TXL 150 models 2.10 A typ.
1.10 A typ.
TXL 220 models 3.00 A typ.
1.60 A typ.
TXL 300 models 3.30 A typ.
1.70 A typ.
TXL 600 models 6.30 A typ.
3.10 A typ.
TXL 1000 models 11.0 A typ.
5.0 A typ.
Input current (at no load)
Vin = 115 VAC
Vin = 230 VAC
TXL 015/025 models 10 mA typ.
17 mA typ.
TXL 035 models 50 mA typ.
55 mA typ.
TXL 120 models 135 mA typ.
125 mA typ.
TXL 220/300 models 115 mA typ.
140 mA typ.
TXL 600 models 210 mA typ.
220 mA typ.
TXL 1000 models 330 mA typ.
350 mA typ.
other models 100 mA typ.
80 mA typ.
Recommended circuit breaker
up to 70Watt models: 5 A
(characteristic C) or slow blow fuse
up to 600 Watt models 10 A
TXL 1000 models 16 A
Output Specifications
Output voltage adjustment range
±10 %
– 35 Watt dual output models: range Vout 1-2
– other multi output models: Vout 1
Regulation
– Input variation
1 % max.
– Load variation (10–100%)
single output models 2 % max.
multiple output models 4 % max. for main output
6 % max. for output 2/3 (20–100 % load)
– Minimum load on main output of multiple output models 0.3 A for TXL 035
(to provide the regulation on the auxilary outputs)
1.0 A for TXL 060
1.5 A for TXL 100
Ripple and noise (20 MHz bandwidth)
3.3VDC output < 50mV
Output 3 (on triple output models) < 1.5% of Vout
all other output voltages < 1.0% of Vout nom.
Output current limitation
105 %–150 % of Iout max.
Overload protection mode
Fold back, automatic recovery
Over voltage protection (only output 1)
115 %–140 % of Vout nom.
(depending on model)
Capacitive load, max.
3.3 VDC–12 VDC output models 10’000 µF
TXL 070: 24 VDC & 48VDC output models 10’000 µF
TXL 100/150: 24 VDC & 48VDC output models 4’700 µF
TXL 035/ 120: 24 VDC & 48VDC output models 1’000 µF
TXL 025/ TXL 220: models 5’000 µF
TXL 300 models 17’000 µF
TXL 600 models 44’000 µF