Operation
a) Arming the door/window alarm
•  Briefly press the “P” button. The red LED briefly lights up 3x and 3 beeps are emitted 
simultaneously.
•  After 5 seconds, the LED briefly lights up 1x and an individual beep can be heard. 
  The door/window alarm is now armed.
  If the door or window is opened, and the distance between the magnet and the 
magnetic contact gets too big, you will hear an alarm sound.
   The time between the activation of the magnetic contact and the alarm can 
adjusted (0, 10 or 20 seconds), see below. In the factory default settings the 
time is set to 0 seconds.
b) Disarming the door/window alarm
•  Enter the password and press the key “P”. The default setting for the password is 
“1234”. 
•  The LED lights up and a long beep is emitted. Afterwards, the door/window alarm is 
disarmed.
   If you enter a wrong password (for example, “4321” instead of “1234”), the 
door/window alarm emits a brief acoustic signal.
 
 If the wrong password is entered 3x consecutively, the alarm sound is trig-
gered.
c) Changing the password
   Changing the password of the default setting (“1234”) is possible only, when 
the door/window alarm is disarmed, see b).
•  Press and hold down the “1” button for approx. 2 seconds. Afterwards, an individual 
beep is emitted. Release the button again.
•  Enter the old password (in the default setting “1234”), 2 beeps will be emitted.
•  Now enter the new password, e.g. “4321”, 3 beeps will be emitted.
  The password has been changed.
   If you remove or replace the batteries, the setting will be lost and the pass-
word will be reset to the default setting “1234”. 
 
 If you forget the password, simply remove the batteries for a few seconds 
and reinsert them. 
 
 Please keep in mind that the password always needs to consist of four dig-
its, e.g. “4321” or “2222”.
d) Setting the time delay
After triggering the magnetic contact (when distance between the magnet and the 
magnetic contact becomes wide enough while opening the door or the window), the 
alarm is activated immediately in the default setting. 
However, if you wish to secure, e.g. an apartment entrance door, you can set a time 
delay of 10 or 20 seconds. This will give you enough time to enter the password without 
triggering the alarm.
   Setting the time delay is possible only, when the door/window alarm is dis-
armed, see b).
•  Time delay of 0 seconds:
  Press and hold down the keys “3” and “4” simultaneously for 5 seconds until the 
LED lights up and a long acoustic signal is can be heard. 
•  Time delay of 10 seconds:
  Hold down the button “3” for 5 seconds until the LED lights up and a long acoustic 
signal can be heard. 
•  Time delay of 20 seconds:
  Hold down the button “4” for 5 seconds until the LED lights up and a long acoustic 
signal can be heard. 
   If you remove or replace the batteries, the setting will be lost and the time 
delay will be reset to the default setting “0 seconds”. 
e) Triggering the alarm
If the door/window alarm is armed and the door or window is opened, the alarm sound 
will start after the time lag.
If the door or window is still not closed after 30 seconds, the alarm starts again after 
the preset delay time.
   If “0 seconds” is set as time delay (default setting), the alarm is triggered 
immediately. 
 
 If you have set the time delay to “10 seconds” or “20 seconds”, the red LED 
flashes quickly during this time, and the alarm is triggered only after this 
time has lapsed. If you enter the correct password during this time lag (af-
terwards, confirm with the “P” button), the door/window alarm will be dis-
armed. 
f) Panic function
•  In order to trigger the alarm sound immediately (e.g. in the event of an assault), 
press and hold down the “P” button for 2 seconds. The alarm is activated for the 
time period of 30 seconds. 
•  Enter the correct password and press the key “P” to stop the alarm.
Maintenance and Cleaning
•  Apart from the occasional battery change, the product is maintenance-free for you. 
•  The outside of the product should only be cleaned with a clean, soft, dry cloth. 
   Do not use aggressive cleaning agents or chemical solutions for this could 
damage the housing (discolouring) or impair the operation. 
Disposal
a) General instructions
   Please dispose of the unserviceable product according to the relevant stat-
utory requirements.
 
 Remove any inserted battery and dispose of it separately from the product.
b) Batteries and rechargeable batteries
As the end user, you are required by law (Battery Ordinance) to return all used bat-
teries/rechargeable batteries; disposal of them in the household waste is prohibited.
   Contaminated  batteries  and  rechargeable  batteries  are  labelled  with  this 
symbol to indicate that disposal in the domestic waste is forbidden. The des-
ignations for the heavy metals involved are: Cd = Cadmium, Hg = Mercury, 
Pb = Lead.
Used batteries, rechargeable batteries as well as coin cells can be returned to collec-
tion points in your municipality, our stores or wherever batteries/rechargeable batter-
ies/coin cells are sold.
You therefore fulfil your statutory obligations and contribute to the protection of the 
environment.
Technical data
Power supply ...................................... 3 batteries of type “LR44”
Volume of the alarm sound ............... 100 dB
Time delay ...........................................  Adjustable (0, 10 or 20 seconds; default setting 0 
seconds)
Password............................................. 4 digits (default setting “1234”)
Ambient conditions ............................  Temperature  0  °C  to  +40  °C,  air  humidity  10%  to 
90% relative, not condensing
Dimensions.......................................... 85 x 46 x 8.5 mm (W x H x D)
Weight .................................................. 30 g