Panasonic Limit switch 400 Vac 10 A Tappet latch MDP5R13Z11 IP65 1 pc(s) MDP5R13Z11 Data Sheet

Product codes
MDP5R13Z11
Page of 10
3
MA160 series
50mm polymeric casing.
2 cable inlets. IP 65
Contact blocks 
  
  
 
Z11   (1NO+1NC) 
MA16
T
••
Z11 MA16
T
••
Z11T 
Z02   (2NC) 
MA16
T
••
Z02 MA16
T
••
Z02T 
X11   (1NO+1NC) 
MA16
T
••
X11 MA16
T
••
X11T 
Y11   (1NO+1NC) 
MA16
T
••
Y11 MA16
T
••
Y11T 
W02  (2NC) 
MA16
T
••
W02 MA16
T
••
W02T 
MA160M series
50mm metal casing.
3 cable inlets. IP 66
Contact blocks 
  
  
 
Z11   (1NO+1NC) 
MA16
T
••
Z11M MA16
T
••
Z11MT 
Z02   (2NC) 
MA16
T
••
Z02M MA16
T
••
Z02MT 
X11   (1NO+1NC) 
MA16
T
••
X11M 
MA16
T
••
X11MT 
Y11   (1NO+1NC) 
MA16
T
••
Y11M 
MA16
T
••
Y11MT 
W02  (2NC) 
MA16
T
••
W02M 
MA16
T
••
W02MT 
MA160
90° adjustable 
head
MA160T
Fully turnable 
head
Z11: Snap action 1NO + 1NC
Z02: Snap action 2 NC
X11: Slow action break before  
 
make 1NO + 1NC
Y11: Slow action make before 
 
break 1NO + 1NC 
W02: Simultaneous slow action  
 2NC
M  A  1  6  
0  T  8  3  Z  1  1  
(T)*
Operating keys
T83, T84, T85
T86, T87, T88, T90
(see page 10)
Electrical connection
see top of page
Ordering Code MA160 (T) series :
Z11:    Snap action contacts
  
 (1NO+1NC)
Z02:    Snap action contacts
  
 (2NC)
X11:    Non overlapping 
  
  Slow action contacts
  
  (1NO+1NC)
Y11:  Overlapping 
  
   Slow action contacts
  
  (1NO+1NC)
W02:    Slow action contacts 
 
(2NC)
Contact blocks
MA160 series
Available contact blocks
Electrical Connection
Replace the symbol “
” with the required 
thread:
0:  for PG 13,5 Cable Gland
2:  for 1/2” NPT Cable Gland
  (with adapter in MA150 and MA160 series)
3:  for PG11 Cable Gland
4:  for M16 x 1,5 Cable Gland
5:  for M20 x 1,5 Cable Gland
*fully turnable head