Jeti Hendheld RC 2.4 GHz No. of channels: 8 80001585 User Manual

Product codes
80001585
Page of 164
computer radio control system
EN
Other parameters displayed in this menu are:
• 
EX  Parameter.  Here  you  can  select  your  sensor  and  its 
parameter which will act as a source for the Vario system. The Climb 
Rate is predefined by default (if the MVARIO EX is detected) but you 
are free to choose one of the other sensors and their parameters (for 
example:  an RPM probe to indicate high revolutions).
• 
Dead  Zone  (negative  and  positive).  This  field  sets  an  area 
around the centre of the range with no acoustic signal. Values are 
relative to the center.
• 
Range (minimum, center and maximum). Here you can define 
the  full  range  of  the  sensor  which  will  be  indicated  by  the  Vario 
system.
The actual value of the sensor and its appropriate Vario output are 
indicated at the bottom of the screen.
 Centre of range
  Negative dead zone
   Positive dead zone
  Silence
 Permanent sound
    Beeping...
 Minimum
Maximum
9.4.4   Voice Output
 
(* depending on equipment)
 
This powerful function makes it easier for all modellers who need to 
know their actual telemetry values often but they don't want to (or 
cannot)  look  at  the  display  because  it  may  be  inconvenient  or 
dangerous.
Voice output for a timer
The first menu row represents settings for the voice output of a timer. 
The actual status of a single timer can be expressed by a synthesized 
voice. If you select the desired timer and a switch, every time the 
switch is activated the actual time is stated aloud. 
If the timer type equals “Laps” type, another menu row equipped 
with  checkbox  appears  below.  In  this  row, “Report  previous  lap” 
allows  you  to  determine  whether  you  want to  hear  the  time  of  a 
current lap which is already running or hear the time of the previous 
lap which has ended recently.
Voice output for telemetry
There are two independent queues dedicated to output telemetry 
values. The first queue repeats its message every x seconds (number 
of seconds elapsed is displayed over the F(1) button). You can also 
assign a switch to enable or disable the repeating of the countdown. 
Every  time  this  switch  is  activated,  the  appropriate  variables  are 
reported by voice and then the countdown starts a new round until a 
timeout is reached.
The second voice queue specifies which variables are reported only 
once, after a single press of a switch. You can select a Trigger switch 
and a list of variables that are reported when the switch is activated.
4.
4.
119