Enter or browse to the locations of the key and certificate, then click Import.
UPS (Uninterruptible Power Supply)
If a UPS (sold separately) is attached, the LinkStation can be automatically shut down for protecting data in the 
event of a power outage.
Plug the power cable of the UPS to a wall socket.
Connect the AC cable of the LinkStation to the UPS.
Connect the UPS and LinkStation using a USB cable or serial cable.
Turn on the UPS, then the LinkStation.
In Advanced Settings, click Management.
Click 
 to the right of "UPS Sync".
Click Edit.
Configure the desired settings, then click OK.
Notes: 
•  If the LinkStation is connected directly to a UPS, select "Sync with UPS connected to this LinkStation". If a 
different LinkStation is connected to the UPS, select "Sync with UPS connected to another LinkStation on the 
same network". After making this selection, enter the IP address of the LinkStation that will be the sync source 
in "Other LinkStation's IP Address".
•  When the LinkStation is rebooted after an automatic shutdown due to a power outage or other power supply 
problem, verify that the power supply has been restored. If the LinkStation is turned on while it is still running