Chapter 10 Appendix
When the Power LED Blinks
White
The power LED will blink white during bootup or shutdown.
Red
If there is an error, the power LED will blink red. The pattern of the blink gives the error code. You can also see any 
errors in NAS Navigator2.
Place of Error Code
Status
10s Place of Error Code
The LED flashes for 1.0 second every 0.3 seconds. This gives the tens place 
of the error code.
1s Place of Error Code
The LED flashes for 0.5 seconds every 0.3 seconds. This gives the ones place 
of the error code.
Error Code
Description
Corrective Action
E07
The firmware is corrupted.
Contact Buffalo technical support for 
assistance.
E11
An error occurred in the fan speed.
Check the fan. Use compressed air or 
tweezers to remove any dust or foreign 
objects. Confirm that the fan is spinning 
normally. If it is not, contact Buffalo 
technical support for assistance.
E12
A rise in the system temperature may 
have exceeded the allowable safety 
value.
Do not place objects in the area 
around the LinkStation. Also, move the 
LinkStation to a cool location.
E14
RAID array x cannot be mounted.
Run the RAID array disk check in Settings.
E15
The bad sectors have reached a 
dangerous level.
Replace the defective drive.
E16
Unable to find hard drive x.
Hard drive x may be disconnected 
or may have failed. Shut down the 
LinkStation and reinstall the hard drive.
E22
Unable to mount drive x.
Format the hard drive. After formatting, 
if the error still appears after rebooting, 
replace the hard drive. If the error 
is displayed again, contact Buffalo 
technical support for assistance.
E23
An error occurred, so the hard drive was 
removed from the RAID array.
Replace the faulty drive.
E30
A hard drive error occurred.
Replace the faulty drive.