Renkforce 3D printer assembly kit RF1000 Single extruder (value.974113) RF1000 Data Sheet

Product codes
RF1000
Page of 114
0
10. Wiring of the Electrical Components
a) General Information
ATTENTION Mains voltage - the connection, installation and wiring of the electrical components must only be perfor-
med by an electrician who is familiar with the applicable safety provisions. Before commissioning, inspection accor-
ding to the applicable safety provisions must be performed by an electrician.
During the connection work, the mains line must never be connected to the mains.
Drag chains
 The drag chains have tabs on one side of the links through which the lines are pushed into the chains. Since the drag
chains can only be bent in one direction, the tab position must be observed (open on the inside > bottom in the follow-
ing figure and open on the outside > top in the following figure). This is indicated when describing the individual work
steps.
When pushing in the lines, always push in the stronger lines first and then the thinner ones. If the tabs of the drag chains
do not return to their initial position when pushed in, the tabs can be pulled back carefully with long-nosed pliers.
The lines must be cleanly placed next to each other in the drag chain and must not be twisted.
When clipping in the drag chain ends into already-installed drag chain end pieces, small flat pliers with which the end
links of the drag chains are latched in the nipples or holes of the end pieces are helpful. Observe that the drag chain ends
latch cleanly with the end pieces. Do not apply any great force, since the plastic material would be damaged otherwise
and the drag chain or end piece would be rendered useless (loss of warranty/guarantee!).
Lines
 Lines that may be swapped are marked with numbers.
These numbers are placed on labels and line ends that are connected to the PCBs in the device socket. Therefore, ob-
serve that the marked line ends must be placed in the device socket when placing the lines.
In the Annex, you will find a wiring plan for the main PCB in which the required line connections are marked.