10.5 Motion control instructions 
Easy Book 
Manual, 03/2014, A5E02486774-AF 
229
 
Parameter and type 
Data type 
Description 
Busy 
OUT 
Bool 
TRUE = The task is being executed. 
CommandAborted 
OUT 
Bool 
TRUE = During execution the task was aborted by another task. 
Error 
OUT 
Bool 
TRUE = An error has occurred during execution of the task. The 
cause of the error can be found in parameters "ErrorID" and 
"ErrorInfo". 
ErrorID 
OUT 
Word 
Error ID for parameter "Error" (Default value: 0000) 
ErrorInfo 
OUT 
Word 
Error info ID for parameter "ErrorID" (Default value: 0000) 
 
The following values were configured in the "Dynamics > General" configuration window: Acceleration = 10.0 and 
Deceleration = 10.0 
 
The axis is moved by an MC_MoveRelative task by the distance ("Distance") 1000.0. When the axis reaches the 
target position, this is signaled via "Done_1". When "Done_1" = TRUE, another MC_MoveRelative task, with travel 
distance 500.0, is started. Because of the response times (for example, cycle time of user program), the axis 
comes to a standstill briefly (see zoomed-in detail). When the axis reaches the new target position, this is signaled 
via "Done_2". 
 
An active MC_MoveRelative task is aborted by another MC_MoveRelative task. The abort is signaled via 
"Abort_1". The axis is then moved at the new velocity by the new distance ("Distance") 500.0. When the new target 
position is reached, this is signaled via "Done_2".