Tripp Lite 2.9kW Single-Phase Hot-Swap PDU, 120V 30A (1 L5-30R, 6 5-15/20R), 2 L5-30P, 10ft & 6ft Cords, 2U Rack-Mount PDUB30 Data Sheet

Product codes
PDUB30
Page of 3
2.9kW Single-Phase Hot-Swap PDU, 120V 30A (1
L5-30R, 6 5-15/20R), 2 L5-30P, 10ft & 6ft Cords, 2U
Rack-Mount
MODEL NUMBER: PDUB30
 
 
Description
Tripp Lite’s Hot-swap PDU systems enable live-replacement of standard UPS systems for maintenance with no
interruption of connected server or networking loads. Dual input power cables support PDU connection to
separate Utility and UPS power sources. Manual transfer switch with lighted status indicators controls the source
of power to connected equipment between Utility and UPS. Set the switch to UPS during normal operation and
connected equipment will receive full-time conditioned power from the UPS. Set the switch to Utility to
momentarily power connected equipment from the Utility line cord and bypass the UPS while the UPS system is
removed and replaced with a fresh one. Once the new UPS is up and running with all data and electrical
connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power
to connected equipment. 
Features
Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or
networking loads
PDUB30 is universally compatible with any Tripp Lite or other brand of 100-127V UPS rated up to 3000VA or 2880 watts with a NEMA L5-30P input cable
2U horizontal rackmount form factor compatible with 2 or 4 post racks
Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual)
Pair of attached L5-30P PDU input cables connect to separate Utility and UPS power sources
6 5-15/20R and 1 L5-30R outlets support critical networking loads in both Utility and UPS operating modes
One additional L5-30R pass-through outlet supports UPS input power cord
Dual input power cables support PDU connection to separate Utility and UPS power sources
Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS
Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS
Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power directly from the Utility line cord while the UPS system
is removed and replaced with a fresh one
Highlights
Single phase 30A 120V Hot-swap
PDU
Enables live replacement of a
standard UPS with zero downtime
2U horizontal rackmount
installation
Compatible with any UPS with a
L5-30P input plug 
Manual transfer switch controls
PDU input power source
Pair of L5-30P input cables
connect to separate Utility and
UPS inputs
7 outlets (6 5-15/20 & 1 L5-30R)
Applications
Hot-swap PDUs are ideal to install
along with standard UPS systems to
ensure that connected networking
equipment will see no power
interruption as the UPS is serviced,
replaced or upgraded
Package Includes
Hot-swap PDU System
2U mounting brackets
User manual with warranty
information