Intel T5470 LF80537GG0252M Data Sheet

Product codes
LF80537GG0252M
Page of 113
Datasheet
31
Electrical Specifications
1.
Refer to 
 for signal descriptions and termination requirements.
2.
In processor systems where there is no debug port implemented on the system board, 
these signals are used to support a debug port interposer. In systems with the debug port 
implemented on the system board, these signals are no connects.
3.
BPM[2:1]# and PRDY# are AGTL+ output-only signals.
4.
PROCHOT# signal type is open drain output and CMOS input.
5.
On-die termination differs from other AGTL+ signals. 
3.8
CMOS Signals
CMOS input signals are shown in 
. Legacy output FERR#, IERR# and other non-
AGTL+ signals (THERMTRIP# and PROCHOT#) use Open Drain output buffers. These 
signals do not have setup or hold time specifications in relation to BCLK[1:0]. However, 
all of the CMOS signals are required to be asserted for more than four BCLKs for the 
processor to recognize them. See 
 for the DC specifications for the CMOS 
signal groups.
3.9
Maximum Ratings
 specifies absolute maximum and minimum ratings only, which lie outside the 
functional limits of the processor. Only within specified operation limits, can 
functionality and long-term reliability be expected.
At conditions outside functional operation condition limits, but within absolute 
maximum and minimum ratings, neither functionality nor long-term reliability can be 
expected. If a device is returned to conditions within functional operation limits after 
having been subjected to conditions outside these limits, but within the absolute 
maximum and minimum ratings, the device may be functional, but with its lifetime 
degraded depending on exposure to conditions exceeding the functional operation 
condition limits.
At conditions exceeding absolute maximum and minimum ratings, neither functionality 
nor long-term reliability can be expected. Moreover, if a device is subjected to these 
conditions for any length of time then, when returned to conditions within the 
functional operating condition limits, it will either not function, or its reliability will be 
severely degraded.
Caution:
Although the processor contains protective circuitry to resist damage from static 
electric discharge, precautions should always be taken to avoid high static voltages or 
electric fields.
NOTES:
1.
For functional operation, all processor electrical, signal quality, mechanical and thermal 
specifications must be satisfied.
Table 5.
Processor Absolute Maximum Ratings
Symbol
Parameter
Min
Max Unit
Notes
1,2
T
STORAGE
Processor Storage Temperature
 -40
 85
°C
3,4,5
T
STORAGE
Processor Storage Temperature
-25
°C
6
V
CC
Any Processor Supply Voltage with 
Respect to V
SS
-0.3
1.45
V
V
inAGTL+
AGTL+ Buffer DC Input Voltage with 
Respect to V
SS
-0.1
1.45
V
V
inAsynch_CMOS
CMOS Buffer DC Input Voltage with 
Respect to V
SS
-0.1
1.45
V