Thermal Specifications and Design Considerations
5.1.2
Thermal Metrology
The maximum and minimum case temperatures (T
C
) are specified in 
. These temperature 
specifications are meant to help ensure proper operation of the processor. 
 illustrates 
where Intel recommends T
C
 thermal measurements should be made. For detailed guidelines on 
temperature measurement methodology, refer to the Intel
®
 Pentium
®
 4 Processor on 90 nm 
Process in the 775-land LGA Package Thermal Design Guidelines.
5.2
Processor Thermal Features
5.2.1
Thermal Monitor
The Thermal Monitor feature helps control the processor temperature by activating the TCC when 
the processor silicon reaches its maximum operating temperature. The TCC reduces processor 
power consumption as needed by modulating (starting and stopping) the internal processor core 
clocks. The Thermal Monitor feature must be enabled for the processor to be operating 
within specifications.
 The temperature at which Thermal Monitor activates the Thermal Control 
Circuit is not user configurable and is not software visible. Bus traffic is snooped in the normal 
manner, and interrupt requests are latched (and serviced during the time that the clocks are on) 
while the TCC is active.
When the Thermal Monitor feature is enabled, and a high temperature situation exists (i.e., TCC is 
active), the clocks will be modulated by alternately turning the clocks off and on at a duty cycle 
specific to the processor (typically 30–50%). Clocks often will not be off for more than 
3.0 microseconds when the TCC is active. Cycle times are processor speed dependent and will 
decrease as processor core frequencies increase. A small amount of hysteresis has been included to 
prevent rapid active/inactive transitions of the TCC when the processor temperature is near its 
maximum operating temperature. Once the temperature has dropped below the maximum 
operating temperature, and the hysteresis timer has expired, the TCC goes inactive and clock 
modulation ceases.
Figure 5-3. Case Temperature (T
C
) Measurement Location
 