80
Datasheet
NOTES:
1.
The TDP specification should be used to design the processor thermal solution. The TDP is 
not the maximum theoretical power the processor can generate. 
2.
Not 100% tested. These power specifications are determined by characterization of the 
processor currents at higher temperatures and extrapolating the values for the 
temperature indicated.
3.
As measured by the activation of the on-die Intel Thermal Monitor. The Intel Thermal 
Monitor’s automatic mode is used to indicate that the maximum T
J
 has been reached. 
Refer to 
 for more details.
4.
The Intel Thermal Monitor automatic mode must be enabled for the processor to operate 
within specification.
5.
T2300E does not support Intel Virtualization Technology.
Table 20.
Power Specifications for the Intel Core Duo Processor SV (Standard Voltage)
Symbol
Processor 
Number
Core Frequency 
& Voltage
Thermal Design 
Power
Unit
Notes
TDP
T2700
T2600
T2500
T2400
T2300
T2300E
N/A
2.33 GHz & HFM V
CC
2.16 GHz & HFM V
CC
 
2.00 GHz & HFM V
CC
1.83 GHz & HFM V
CC
1.66 GHz & HFM V
CC
1.66 GHz & HFM V
CC
1.00 GHz & LFM V
CC
31
31
31
31
31
31
13.1
W
At 100°C
Notes 1, 4, 
Symbol
Parameter
Min
Typ
Max
Unit
Notes
P
AH,
P
SGNT
Auto Halt, Stop Grant Power
at HFM V
CC
at LFM V
CC
15.8
4.8
W
At 50°C
Note 2
P
SLP
Sleep Power 
at HFM V
CC
at LFM V
CC
15.5
4.7
W
At 50°C
Note 2
P
DSLP
Deep Sleep Power 
at HFM V
CC
at LFM V
CC
10.5
3.4
W
At 35°C
Note 2
P
DPRSLP
Deeper Sleep Power
2.2
W
At 35°C
Note 2
P
DC4
Intel® Enhanced Deeper Sleep Power 
1.8
W
At 35°C
Note 2
T
J
Junction Temperature
0
100
°C
Notes  3,  4