Intel U1300 LE80538UE0042M Data Sheet

Product codes
LE80538UE0042M
Page of 53
 
Errata 
 
 
 
Specification Update  
 19
 
Errata 
AE1. 
FST Instruction with Numeric and Null Segment Exceptions May Take 
Numeric Exception with Incorrect FPU Operand Pointer 
Problem: 
If execution of an FST (Store Floating Point Value) instruction would generate both 
numeric and Null segment exceptions, the numeric exceptions may be taken first and 
with the Null x87 FPU Instruction Operand (Data) Pointer. 
Implication:  Due to this erratum, on an FST instruction the processor reports a numeric exception 
instead of reporting an exception because of a Null segment. If the numeric exception 
handler tries to access the FST data it will get a #GP fault. Intel has not observed this 
erratum with any commercially-available software, or system. 
Workaround: The numeric exception handler should check the segment, and if it is Null, avoid 
further access to the data that caused the fault. 
Status: 
For the steppings affected, see the 
Summary Tables of Changes
.  
AE2. 
Code Segment Limit Violation May Occur on 4-Gbyte Limit Check 
Problem: 
Code Segment limit violation may occur on 4-Gbyte limit check when the code stream 
wraps around in a way that one instruction ends at the last byte of the segment and 
the next instruction begins at 0x0. 
Implication:  This is a rare condition that may result in a system hang. Intel has not observed this 
erratum with any commercially-available software, or system. 
Workaround: Avoid code that wraps around segment limit. 
Status: 
For the steppings affected, see the 
Summary Tables of Changes
.  
AE3. 
Errata –Removed