Intel S1400SP4 BBS1400SP4 User Manual

Product codes
BBS1400SP4
Page of 159
 
Intel® Light Guided Diagnostics
 
Intel® Server Board S1400SP TPS
 
 
 
Revision 1.0 
Intel order number G64248-001 
96 
 
Figure 28. Memory Slot Fault LED Locations 
10.1  System ID LED 
The server board includes a blue system ID LED which is used to visually identify a specific 
server installed among many other similar servers. There are two options available for 
illuminating the System ID LED: 
1.  The front panel ID LED Button is pushed, which causes the LED to illuminate to a solid 
on state until the button is pushed again. 
2.  An IPMI Chassis Identify command is remotely entered, which causes the LED to blink. 
 
The System ID LED on the server board is tied directly to the System ID LED on system front 
panel if present. 
10.2  System Status LED 
The server board includes a bi-color System Status LED. The System Status LED on the server 
board is tied directly to the System Status LED on the front panel (if present). This LED 
indicates the current health of the server. Possible LED states include solid green, blinking 
green, blinking amber, and solid amber.  
 
When the server is powered down (transitions to the DC-off state or S5), the BMC is still on 
standby power and retains the sensor and front panel status LED state established before the 
power-down event. 
 When AC power is first applied to the system, the status LED turns solid amber and then 
immediately changes to blinking green to indicate that the BMC is booting. If the BMC boot 
process completes with no errors, the status LED will change to solid green.